Amber DT-two Programmable Thermostat User Guide
1.
Room Temp Calibration: Calibrate the room temp detected by room sensor.
Floor Temp Calibration: Calibrate the floor temp detected by floor sensor.
Anti-frozen Switch: This option allows you to turn frost protection on / off.
Anti-frozen Temperature: Adjust the frost protection trigger temperature.
Floor temperature limit: If you choose both sensors, floor temp limit must be set to protect floor.
2.
3.
4.
5.
6.
Temperature Tolerance: The value is 1°C. The thermostat will start to heat when the actual temperature is 1°C
lower than set temperature and stop heating when the actual temperature is 1°C higher than set temperature.
7.
°F / °C: °C and °F can be selected.
8.
Sensor selection:
Floor sensor: Floor sensor must be used when the thermostat is used with electric underfloor heating or is
not installed in the same room as the heated floor.
Room sensor: Heating controlled with the air sensor only.
Both sensors: Controlling roomtemperaturewithfloortemperature limitation as perfloortemperature limit above.
9.
Schedule: Select a weekly timer schedule. There are two options:
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
10.
Time delay: This option is a time delay should you inadvertently make a change that you wish to reverse.
11.
Adaptive function: After several days of installation and use, Adaptive function ensures that the required
temperature has already been reached when the next event begins.
12.
13.
Open window: This function only works when room sensor or air sensor are selected. The thermostat with this
function will shut off automatically for 15 minutes if it detects a sudden drop in temperature.
Language: There are four languages: English/German/Spanish/French.
14 & 15. Power Set & Energy Use: This option allows you to enter the various data used to calculate energy use. Then use
this information to calculate electricity consumption.
16.
17.
Sensor type: This option allows floor sensor type selection if replacing a 3rd party thermostat and cannot
replace the existing floor sensor. Please ensure B3950-10K is selected if using the sensor that came in the box
with this thermostat.
Factory Reset: All parameters are restored to default values.
15
| General | Details |
|---|---|
| Name | Amber DT-two Programmable Thermostat User Guide |
| Make | Amber |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.38 MB |