Wire the device as illustrated below.
The product allows for wiring of cables with cross
section of up to 1X2.5mm2
LED PATTERNS
HEATIT ZM
THERMOSTAT
16A
GREEN
RED
Successful
Unsuccessful
Read the full manual at:
manuals.heatit.com
Quick Guide
01.09.21 Ver 2021-A
Last
Load
TECHNICAL DATA
Protocol
Chip
Z-Wave
Z-Wave 700 chip
NTC
L
N
Rated voltage 230VAC 50Hz
Max load 3600W 165A
Power Consum. <1W
Ambient temp. 5°C to 40°C (-30°C to 70°C storage)
Configuration button
N
Power connection (Neutral) 230VAC.
Output. Load needs to be connected between
O and Neutral.
Humidity
Range RF
IP Code
Max 95% RH
Min. 40 meters
IP 20
O
L
L
Power connection (Live) 230VAC.
Power connection (Live) 230VAC.
Size (DxWxH)
46 x 45 x 25mm
NTC10K NTC Temperature sensor.
Approvals
Z-Wave Plus V2,
INTRODUCTION
CE,
NTC10K NTC Temperature sensor.
Heatit ZM Thermostat 16A is an electronic
thermostat for electrical floor heating designed
for inwall installations. The thermostat allows you
to control your electrical heating through your
Z-Wave network. The module is equipped with a
16A single pole relay. The thermostat requires you
to connect an external sensor which is included
with the device. The device can withstand a max
load of 16A at 230VAC.
EN 60669-1:2018,
ADD/REMOVE
EN 60669-2-1:2004 + A1:2009,
EN 60669-1:2004/A12:2010,
EN 60669-2-5:2016,
1. Set the primary controller to add mode
(secure/non-secure).
2. Press the configuration button 3 times in rapid
succession.
IEC 965-2-1, EN 62479:2010,
ETSI EN 301 489-3 V2.1.1(2017-03),
ETSI EN 300 220-2 V3.1.1(2017-02),
RoHs 2002/95/EG,
3. The device LED will flash green when the
adding procedure has been successfully
initiated.
WEE 2002/96/EC
When the device has been included in the home
automation system, the LED will stay green for
3 seconds. The device is now ready for use with
default settings.
The device is maintenance-free. Indoor use only.
STATEMENT REGARDING PRODUCTS
FROM MULTIPLE MANUFACTURERS
Please read this before installation
This device may be used with all devices certified
with the Z-Wave Plus™ certificate and should
be compatible with such devices produced by
any manufacturer. Every primary controller is
different depending on the manufacturer, their
target audience and intended use/application.
Please review the functionalities implemented
by the primary controller you intend to use with
our Z-Wave Plus certified device to ensure that
it provides the necessary controls to take full
advantage of our product’s capabilities.
If the adding process was unsuccessful, the LED
will show a red light for 3 seconds. Please perform
a ”remove device”process and try to add again. If
the LED goes red again, please see the full manual
for more information regarding adding, removing
and factory reset.
Adding/removing mode is indicated on the
device by a flashing green lights. This lasts until
timeout occurs after 90 seconds, or until the
device has been added/removed from the
network.
INSTALLATION
Heatit Controls AB can not be held liable for typographical
errors, other errors or omittances in our information.
Product specifications may change without further notice.
All electrical installations must be carried out by a licensed
electrician. The product must be installed in accordance
with national building codes and our installers manual.
Installation must be done by a qualified electrician
in accordance with national building codes.
Before installation, disconnect the power to the
device. During installation of the device, power
to the device must be disconnected AT ALL TIMES!
NB! When the device is removed from the
gateway, the parameters are not reset. To reset the
parameters, see the full manual.
Heatit Controls AB
l
Läkarvägen 4, 454 31 BRASTAD, SWEDEN
post@heatit.com – www.heatit.com
Phone: +47 61 18 77 77
l
| General | Details |
|---|---|
| Name | 4512673 Heatit ZM Thermostat 16A User Guide |
| Make | HEATIT |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual

HEATIT Z-TRM3 Thermostat User Guide

Heatit Z-TEMP2 Thermostat Installation Guide

heatit Z-TRM3 WiFi Thermostat Instruction Manual

HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

HEATIT 54 304 59 DIN Smart Thermostat Installation Guide

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

HEATIT Z-TEMP3 Thermostat User Guide

heatit ET-7AW Touchscreen Programmable Thermostat User Manual

4512673 Heatit ZM Thermostat 16A User Guide Overview
Summary of Contents
- Page 1: Wire the device as illustrated below. The product allows for wiring of cables with cross section of up to 1X2.5mm². Heatit ZM Thermostat 16A is an electronic thermostat for electrical floor heating designed for in-wall installations. The thermostat allows you to control your electrical heating through your Z-Wave network. The module is equipped with a 16A single pole relay. The thermostat requires you to connect an external sensor which is included with the device. The device can withstand a max load of 16A at 230VAC. The device is maintenance-free. Indoor use only. All electrical installations must be carried out by a licensed electrician. Installation must be done by a qualified electrician in accordance with national building codes.
- Page 2: Koble til ledningene som vist på tegningen under. Maks diameter for tilkoblede kabler er 1x2,5mm. LED indikasjonmønster. Heatit ZM. Termostat. Maks belastning 3600W 16A. Omgivelsestemperatur 5°C til 40°C (-30°C til 70°C lagring). Produktet trenger ikke vedlikehold. Kun for innendørs bruk. Produktet skal installeres av autorisert installatør i henhold til norske bygg-forskrifter. Heatit Controls AB tar forbehold om typografiske feil, andre feil eller mangler i vår informasjon.