Home > HEATIT > 4512673 Heatit ZM Thermostat 16A User Guide

4512673 Heatit ZM Thermostat 16A User Guide

Wire the device as illustrated below.  
The product allows for wiring of cables with cross  
section of up to 1X2.5mm2  
LED PATTERNS  
HEATIT ZM  
THERMOSTAT  
16A  
GREEN  
RED  
Successful  
Unsuccessful  
Read the full manual at:  
manuals.heatit.com  
Quick Guide  
01.09.21 Ver 2021-A  
Last  
Load  
TECHNICAL DATA  
Protocol  
Chip  
Z-Wave  
Z-Wave 700 chip  
NTC  
L
N
Rated voltage 230VAC 50Hz  
Max load 3600W 165A  
Power Consum. <1W  
Ambient temp. 5°C to 40°C (-30°C to 70°C storage)  
Configuration button  
N
Power connection (Neutral) 230VAC.  
Output. Load needs to be connected between  
O and Neutral.  
Humidity  
Range RF  
IP Code  
Max 95% RH  
Min. 40 meters  
IP 20  
O
L
L
Power connection (Live) 230VAC.  
Power connection (Live) 230VAC.  
Size (DxWxH)  
46 x 45 x 25mm  
NTC10K NTC Temperature sensor.  
Approvals  
Z-Wave Plus V2,  
INTRODUCTION  
CE,  
NTC10K NTC Temperature sensor.  
Heatit ZM Thermostat 16A is an electronic  
thermostat for electrical floor heating designed  
for inwall installations. The thermostat allows you  
to control your electrical heating through your  
Z-Wave network. The module is equipped with a  
16A single pole relay. The thermostat requires you  
to connect an external sensor which is included  
with the device. The device can withstand a max  
load of 16A at 230VAC.  
EN 60669-1:2018,  
ADD/REMOVE  
EN 60669-2-1:2004 + A1:2009,  
EN 60669-1:2004/A12:2010,  
EN 60669-2-5:2016,  
1. Set the primary controller to add mode  
(secure/non-secure).  
2. Press the configuration button 3 times in rapid  
succession.  
IEC 965-2-1, EN 62479:2010,  
ETSI EN 301 489-3 V2.1.1(2017-03),  
ETSI EN 300 220-2 V3.1.1(2017-02),  
RoHs 2002/95/EG,  
3. The device LED will flash green when the  
adding procedure has been successfully  
initiated.  
WEE 2002/96/EC  
When the device has been included in the home  
automation system, the LED will stay green for  
3 seconds. The device is now ready for use with  
default settings.  
The device is maintenance-free. Indoor use only.  
STATEMENT REGARDING PRODUCTS  
FROM MULTIPLE MANUFACTURERS  
Please read this before installation  
This device may be used with all devices certified  
with the Z-Wave Plus™ certificate and should  
be compatible with such devices produced by  
any manufacturer. Every primary controller is  
different depending on the manufacturer, their  
target audience and intended use/application.  
Please review the functionalities implemented  
by the primary controller you intend to use with  
our Z-Wave Plus certified device to ensure that  
it provides the necessary controls to take full  
advantage of our product’s capabilities.  
If the adding process was unsuccessful, the LED  
will show a red light for 3 seconds. Please perform  
a ”remove deviceprocess and try to add again. If  
the LED goes red again, please see the full manual  
for more information regarding adding, removing  
and factory reset.  
Adding/removing mode is indicated on the  
device by a flashing green lights. This lasts until  
timeout occurs after 90 seconds, or until the  
device has been added/removed from the  
network.  
INSTALLATION  
Heatit Controls AB can not be held liable for typographical  
errors, other errors or omittances in our information.  
Product specifications may change without further notice.  
All electrical installations must be carried out by a licensed  
electrician. The product must be installed in accordance  
with national building codes and our installers manual.  
Installation must be done by a qualified electrician  
in accordance with national building codes.  
Before installation, disconnect the power to the  
device. During installation of the device, power  
to the device must be disconnected AT ALL TIMES!  
NB! When the device is removed from the  
gateway, the parameters are not reset. To reset the  
parameters, see the full manual.  
Heatit Controls AB  
l
Läkarvägen 4, 454 31 BRASTAD, SWEDEN  
post@heatit.com – www.heatit.com  
Phone: +47 61 18 77 77  
l
GeneralDetails
Name4512673 Heatit ZM Thermostat 16A User Guide
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.14 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

4512673 Heatit ZM Thermostat 16A User Guide
Get the free PDF manual for the 4512673 Heatit ZM Thermostat 16A User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

4512673 Heatit ZM Thermostat 16A User Guide Overview

Summary of Contents

  • Page 1: Wire the device as illustrated below. The product allows for wiring of cables with cross section of up to 1X2.5mm². Heatit ZM Thermostat 16A is an electronic thermostat for electrical floor heating designed for in-wall installations. The thermostat allows you to control your electrical heating through your Z-Wave network. The module is equipped with a 16A single pole relay. The thermostat requires you to connect an external sensor which is included with the device. The device can withstand a max load of 16A at 230VAC. The device is maintenance-free. Indoor use only. All electrical installations must be carried out by a licensed electrician. Installation must be done by a qualified electrician in accordance with national building codes.
  • Page 2: Koble til ledningene som vist på tegningen under. Maks diameter for tilkoblede kabler er 1x2,5mm. LED indikasjonmønster. Heatit ZM. Termostat. Maks belastning 3600W 16A. Omgivelsestemperatur 5°C til 40°C (-30°C til 70°C lagring). Produktet trenger ikke vedlikehold. Kun for innendørs bruk. Produktet skal installeres av autorisert installatør i henhold til norske bygg-forskrifter. Heatit Controls AB tar forbehold om typografiske feil, andre feil eller mangler i vår informasjon.