WTE WT-100 Zigbee Thermostat User Manual
Time programming instructions
Long press the M key to enter the programming setting, short press the M key to switch
options, press the
or
key to adjust the parameter of each option, and press the
key to exit and save mode.
Tima
Adjustment
Temperature
adjustment
Key
M
Options
Icon
Time
Defaults
1
2
3
4
5
6
1
2
06:00
08:00
11:30
12:30
17:00
22:00
08:00
23:00
20°C
16°C
16°C
16°C
22°C
16°C
22°C
16°C
Working
days
Holidays
Advance options
When POWER OFF, press the M key and the
option setting.
key for 5 seconds to enter the advanced
Press M to enter the next option, press
Level option.
and
to adjust, and press
to exit the heigh
Temperature
compensation
The default value of the calibration room temperature is -
2°C. Press the up and down keys to adjust. The adjustable
range is 9.9°C to -9.9°C.
1
2
Sensor selection
The temperature sensor is selected as IN by default. Press
the up and down keys to adjust as IN respectively,
indicating that the internal. ALL means all internal sensors
are selected OUT means external sensors are set.
The default temperature limit value is 60°C. Press the up
and down keys to adjust the range from 35°C to 60°C.
The default temperature difference is set to 1°C. Press the
up and down keys to adjust the range to 0.5-10 degrees.
Set the default anti-freeze function to OFF, display OFF,
press the up key to turn on anti-freeze and display ON.
5: Two-day weekend
Modify the
temperature limit
Temperature
difference start
Antifreeze function
3
4
5
Holiday option and
turn off weekly
programming
6: Single day off
7: No rest
6
OFF: Turn off programming
7