Wengart TP808 Low Voltage Thermostat User Guide
Example Schedule
Period
Week
Short press fan button to select cycle.Press
comfirm this function running.
to
Sleep
22:00
Get up
Go outside
8:00
Go home
18:00
If you want to circulate the air in your home using your
indoor blower fan, you can set this feature at the
thermostat. A percentage is selected to indicate how
often the fan should run each hour, You can set 5%
increments from 10% – 100%.
6:00
Time
Mon-Sun Cool Temp
83
℉
83
℉
79
℉
72
℉
79
℉
72
℉
Heat Temp
61
℉
61
℉
Wiring Diagram
EXAMPLE:
If you set the Circulating Fan to 50%, the fan will
run 30 minutes every hour.
RH: Power for heating, 24V
RC: Power for cooling, 24V
G: Indoor blower (fan)
If any heat/cool cycles occur during the hour, their
runtime is subtracted from the overall fan run time
Item 21 Select UV lamp replacement run time
This is the reminder to change UV lamp . Select
starts to counting for 0 day to 360 days. The thermostat
will display “Chg UV” when UV time (Xxdays).
APP will also reminder
S: Connect to S on C-wire adapter
O/B: Changeover (reverse valve) connection for heat
pump or zone panel systems
Y: First outdoor stage cooling on conventional systems
or first heat and cool on heat pump systems
Y2: Second outdoor stage cooling on conventional
systems or second heat and cool on two stage
heat pump systems or humidifier
NTC+: Outer Sensor+
NTC-: Outer Sensor-
C: Common wire, 24V
W /AUX: First indoor stage heat on conventional
systems or first stage auxiliary
W2/E: Secondary indoor heat for conventional systems
item 22 Chg pad replacement run time
This is the reminder of replacement run time of Chgpad .
Select starts to counting for 0 day to 360 days.
The thermostat will display “Chg Pad” when Chg pad
(XXdays).LCD will display.APP will also reminder
item 23 Chg Filter replacement run time
This is the reminder of replacement run time of Chg Filter .
Select starts to counting for 0 day to 360 days.
The thermostat will display “Chg Filter” when Chg Filter
(XXdays).LCD will display.APP will also reminder
All these three items you could check according
to bellow steps.
Long press Menu button over 7seconds to enter
check page.Short press menu button to next item.
Press+ and - button over 7seconds to reset.
emergency heat on heat pump systems
Vocation function
Long press fan button over 7seconds to enter Vocation
mode.Short press fan button check days->cool temp
->heat temp.Long press
button for 7 sec.When you
see the parmeter flash.Short press fan button to set
the paremeters.Short press to excit
Setting Energy Saving Mode
Short press
button to enter energy saving.The LCD
Sensor broken
Er1:Inner sensor broken or not work
Er2:External sensor broken or not work
will show on. If you need change engery saving temp.
Long press button and button at the same
time over 7seconds.Short press time button to set
The order is ECO cool temp->ECO heat temp
Installing your thermostat
Configuration Menu
Short
This product is suitable for US standard wall box.
1. Connect the wire of power and other equipment into
the terminals.Fix the wall plate into the wall box
by a screwdriver.
Menu item
Notes
Default
No.
Selection Range
Icon
Set Up HVAC Equipment
(Outdoor)
Outdoor Setup
AC1/AC2/HP1/HP2/None
OUT
AC2
EL2
1
2
3
4
When you select heat pump
(AUX) GA1/EL1/NON option
Set Up HVAC Equipment
(Indoor)
Indoor Setup
GA1/GA2/EL1/EL2/None
IND
Only Item 1 select
OUT:HP1 HP2 workable
When you select heat pump
(EMER) GA1/EL1/NON option
Outdoor equipment 1
Circulatio fan switch
INE
FA1
NON
ON
ON/OFF
If you set the Circulating Fan to 50%,
the fan will run 30 minutes every hour.
If any heat/cool cycles occur during
the hour, their runtime is subtracted
from the overall fan run time.
Circulatio fan Setting range
FA2
30%
ON
5
10%-100%
ON/OFF
Auto Mode
AUT
CO1
CO2
OB
6
7
8
Compressor 1 delay
1-5min
1-5min
3
3
0
Compressor 2 delay
Only Item 1 select out.
HP1/HP2 workable
Reversing Valve Position
O/B O:Cool B:Heat
ON/OFF
9
10
External sensor
OFF
SEN
ON:Set “EITHER AUX/E”control the
same time
OFF: if you want to setup and control
of Auxiliary and Emergency heating
separately . This item is only displa
yed if Item1 is set to Heat Pump AND
if item 2 GA1/EL1.Item3 GA1/EL1
Aux/E stages =
Both AUX/EMER
APU
ON/OFF
ON/OFF
OFF
11
12
2. Connect the LCD board into the wall plate
Item 1 should be HP1/HP2
Item 2 should be GA1/EL1
Item10 should ON.
OFF
AUX lockout
APL
AO
Only all of three items workable
Item 1 should be HP1/HP2
Item 2 should be GA1/EL1
Item10 should ON.Item 12 ON.
Only all of four items workable
AUX lockout Temp
36
OFF
32
-15~20 , 5-68
ON/OFF
13
14
15
Item 1 should be HP1/HP2
Item 2 should be GA1/EL1
Item 10 should ON.
Only all of three items workable
Item 1 should be HP1/HP2
Item 2 should be GA1/EL1
Item10 should ON.Item 13 ON.
Only all of four items workable
Heat Pump Lockout
COL
AC
Heat Pump Lockout Temp
-15~20 , 5-68
Temperature Compensation
C/F selecable
CL
FC
AH
0
F
-9~9
16
17
18
WARNING: Please arrange the professional technician
to install this product according to installation drawing
and instruction.
RISK OF ELECTRICAL SHOCK. Disconnect power
supply before making electrical connection. Contact
with components carrying hazardous voltage can
cause electrical shock and may result in severe
personal injury or death.instruction.
F/C
Maxmum Temperature
Range
20-50℃,68-95℉
95
Minimum Temperature
Range
AL
5-20℃,41-68℉
41
19
Time
12 24
0-36
12
12
TI
20
21
UV Reminder time setting
UU
ChagPad Reminder Time
Setting
0-36
0-36
12
12
PAD
FIL
22
23
ChagFilter Reminder Time
Setting
Note:
Item 4: Circulating fan
| General | Details |
|---|---|
| Name | Wengart TP808 Low Voltage Thermostat User Guide |
| Make | WENGART |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.89 MB |

Wengart TP808-S-2 Low Voltage Thermostat User Guide

Wengart TP808-3 Heat Pump Thermostat User Guide

Wengart TP808-3 7 Day Programmable Thermostat User Manual

Wengart TP808 Wi-Fi Low Voltage Thermostat User Guide

Wengart WG603 Home Smart Thermostat User Guide