WATTS IOM-T-563 Tekmar WiFi Thermostat Installation Guide
Setup - Temp
Setting
Range
Default
Screen Page 1
FLOOR MIN - WAKE
Select the floor temperature while in the wake schedule.
Applies when there is both a floor and an air sensor.
Off, 40 to 95°F
Off
Off
Off
Off
Off
Off, 4.5 to 35.0°C
FLOOR MIN - LEAVE
Select the floor temperature while in the leave schedule.
Applies when there is both a floor and an air sensor.
Off, 40 to 95°F
Off, 4.5 to 35.0°C
FLOOR MIN - RETURN
Select the floor temperature while in the return schedule.
Applies when there is both a floor and an air sensor.
Off, 40 to 95°F
Off, 4.5 to 35.0°C
FLOOR MIN - SLEEP
Select the floor temperature while in the sleep schedule.
Applies when there is both a floor and an air sensor.
Off, 40 to 95°F
Off, 4.5 to 35.0°C
FLOOR MIN - AWAY
Select the floor temperature while in away.
Applies when there is both a floor and an air sensor.
Off, 40 to 95°F
Off, 4.5 to 35.0°C
FLOOR MAX
Off, 40 to 95°F
Select the maximum floor temperature. This protects the
floor covering from over heating. Applies when there is a
floor sensor.
Off
Off, 4.5 to 35.0°C
Screen Page 2
Off, 40 to 95°F
62°F
HEAT TO AWAY
Select the heating temperature when away.
Off, 4.5 to 35.0°C
Off, 40 to 95°F
16.5°C
HEAT TO MIN LIMIT
Select the minimum heating temperature limit.
Off
Off
Off
Off
Off
Off, 4.5 to 35.0°C
Off, 40 to 95°F
HEAT TO MAX LIMIT
Select the maximum heating temperature limit.
Off, 4.5 to 35.0°C
Off, 45 to 100°F
Off, 7.0 to 38.0°C
Off, 45 to 100°F
Off, 7.0 to 38.0°C
Off, 45 to 100°F
Off, 7.0 to 38.0°C
COOL TO AWAY
Select the cooling temperature when away.
COOL TO MIN LIMIT
Select the minimum cooling temperature limit.
COOL TO MAX LIMIT
Select the maximum cooling temperature limit.
Screen Page 3
Off, 40 to 100°F
Off, 4.5 to 38.0°C
Off, 40 to 100°F
Off, 4.5 to 38.0°C
WARM WEATHER SHUT DOWN
Select the outdoor temperature at which the heating is shut off.
Off
Off
COLD WEATHER SHUT DOWN
Select the outdoor temperature at which the cooling is shut off.
HEAT PUMP BALANCE POINT
Select the outdoor temperature at which the heat pump is
shut off and the backup heat source is operated exclusively.
Off, -22 to 70°F
Off
Off, -30.0 to 21.0°C
22
| General | Details |
|---|---|
| Name | WATTS IOM-T-563 Tekmar WiFi Thermostat Installation Guide |
| Make | WATTS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.63 MB |

WATTS IOM-T-564 tekmar Invita WiFi Thermostat Instruction Manual

WATTS BT-A03 RF Electronic Room Thermostat Installation Guide

WATTS TEK564 Invita WiFi Thermostat Instruction Manual

WATTS WTC-ES Contact Thermostat User Manual

WATTS 563 WiFi Thermostat User Manual

WATTS W561 WiFi Thermostat Instruction Manual

WATTS Tekmar Wi-Fi Thermostat Instruction Manual