sinope Smart Low Voltage Thermostat TH1400WF Installation Guide
PARAMETERS THAT CAN BE CONTROLLED
FROM THE DEVICE (continued):
USER SETTINGS
The thermostat features two temperature
control modes:
All of the thermostat's settings can be set through the
Neviweb app. However, if you have not created your
account and wish to change the temperature format or the
control cycle, you need to:
Name
Parameters & settings
Display
#
Max
Floor
Maximum floor temperature limit
7 °C to 36 °C – (Default: OFF)
A mode (default): Regulation of ambient temperature with
the possibility to limit floor temperature through an external
temperature sensor.
4
Lower the setpoint to its minimum and hold the
10 seconds to access the menu.
button for
Min
Floor
Minimum floor temperature limit
5 °C to 36 °C – (Default OFF)
5
6
F mode: Regulation of floor temperature through an external
temperature sensor with the possibility to limit
ambient temperature.
Press the
or the
button to change the setting.
Cycle lenght / Main output
15 sec, 5 min, 10 min, 15 min, 20 min,
25 min, 30 min – (Default: 15 min)
Cyc
Press the
and the
buttons simultaneously to save and go
to the next parameter. Continue to press until the end of the list
to exit the menu.
Cycle lenght / Auxiliary output
OFF, 15 sec, 5 min, 10 min, 15 min, 20 min,
25 min, 30 min – (Default: OFF)
Aux
Cyc
7
PARAMETERS THAT CAN BE CONTROLLED
FROM THE DEVICE:
Floor sensor
10K or 12K – (Default: 10K)
Sens
PE
8
9
Circulator pump's anti-seizure
ON or OFF (Default: OFF)
Name
Parameters & settings
Display
#
Temperature format
°C or °F – (Default: °C)
Temp
1
Control mode of thermostat
A (Air), F (Floor) – (Default: A)
Control
2
3
10 sec.
Maximum ambient temperature limit
5 °C to 36 °C – (Default OFF)
Max
Air
DISCONNECT YOUR THERMOSTAT FROM THE
WI-FI ROUTER OR THE NEVIWEB APP
PARAMETERS THAT CAN BE CONTROLLED FROM
THE DEVICE (CONTINUED):
To disconnect your thermostat from the Wi-Fi router press the
6) et 7) Main and auxiliary output cycle length
3) Maximum limit of the ambient
temperature (F mode)
and
buttons simultaneously for 10 seconds. The
symbol will disappear from the display.
The thermostat has a main and an auxiliary output.
Select the appropriate cycle length based on your
heating system. The selection of an inappropriate
cycle length may damage your unit.
Thermostat limits floor heating so as not to exceed the set ambient
temperature limit
4) Maximum floor temperature limit (A mode)
Minimum cycle length
0.15
5
10
15
20 25 30
The thermostat limits floor heating to the set temperature to ensure
it does not exceed the selected limit. This parameter is ideal for
protecting engineered wood floors. (Verify with your flooring
manufacturer to determine heat limit.)
Convector or baseboard heater
activated by electronic relay (SSR)
Fan-forced convector activated
by electronic relay (SSR)
This parameter is only usable when a floor sensor is connected to
the thermostat.
Fan-forced convector or
baseboard heater activated by
mechanical relay
Hydronic heating pump system
Furnace
10 sec.
5) Minimum floor temperature limit (A mode)
The thermostat limits the minimum temperature of the floor in
order to keep it at a comfortable temperature.
9) Circulator pump's anti-seizure
This parameter can only be used when a floor sensor is
connected to the thermostat.
To remove your thermostat from Neviweb, press Delete in
the thermostat settings.
When the thermostat is not heating for an extended period, this
parameter will activate the main output during 1 minute every
24 hours to ensure the hydronic system pump does not seize.
TECHNICAL SPECIFICATIONS
Use of the Works with Apple badge means that an accessory has been designed to work
specifically with the technology identified in the badge and has been certified by the developer
to meet Apple performance standards. Apple is not responsible for the operation of this device
or its compliance with safety and regulatory standards.
Operating voltage: 24 Vac
Maximum load: 1 Amp
HomeKit is a trademark of Apple Inc.
Setpoint range: 5 ˚C to 36 ˚C (41 ˚F to 97 ˚F)
Display range: 0 ˚C to 70 ˚C (32 ˚F to 99 ˚F)
Resolution: 0,5 ˚C ( 1 ˚F)
Storage: -20 ˚C to 50 ˚C (-4 ˚F to 122 ˚F)
Auxiliary output: 24 Vac / Vdc / 0.1 A
Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.
App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play
and the Google Play logo are trademarks of Google Inc.
The Wi-Fi CERTIFIED™ Logo is a certification mark of Wi-Fi Alliance®
Protocol: Wi-Fi
Standard: IEEE 802.11 b/g/n
Frequency: 2.4 GHz
Transmitter Module IC : 21098-ESPWROOM32 / FCC ID: 2AC7Z-ES-
PWROOM32
Compatible with:
• Baseboard heater activated by mechanical relay or
electonic relay (SSR)
• Fan-forced convector activated by mechanical relay
or electronic relay (SSR)
• Electric floor heating (activated by a relay)
• Hydronic floor heating
• Hydronic heating system
This device complies with Industry Canada license exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device does not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired operation
of the device.
3-year limited warranty
SINOPE TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3-year period from the date of purchase,
under normal use and service, when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any transportation costs that may be
incurred by the consumer. Nor does it cover a product that has been improperly
installed, misused or accidentally damaged.
The obligation of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty,
will be to supply a new unit and this releases the manufacturer from paying the
installation costs or other secondary charges linked to replacing the unit or the
components.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment OFF and ON, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Furnace (without fan control)
Controlling this HomeKit-enabled accessory automatically
and away from home requires a HomePod, Apple TV, or
iPad set up as a home hub. It is recommended that you
update to the latest software and operating system.
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
660-0737-0006-B
| General | Details |
|---|---|
| Name | sinope Smart Low Voltage Thermostat TH1400WF Installation Guide |
| Make | sinope |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.37 MB |

sinope TH1134ZB-HC Smart Line Voltage Thermostat Owner’s Manual

sinope Smart Floor Heating Thermostat TH1310WF Installation Guide

sinope TH1124NP Non Programmable Thermostat for Electric Heating Owner’s Manual

sinope TH1300ZB-C4 3600W Smart Floor Heating Thermostat Installation Guide
sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide

sinope TH1134ZB Smart Line Voltage Thermostat Installation Guide

sinope TH1500ZB Smart Double Pole Thermostat Installation Guide

sinope TH1500WF Smart Double Pole Thermostat Installation Guide