SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
Zigbee Room Thermostat, wired and wireless, battery
powered
RDZ100ZB, RDZ101ZB
For heating systems
●
●
●
Room temperature control
Communicates with Connected Home Hub via Zigbee network
2-position/TPI control with On/Off output for heating
– RDZ100ZB: With built-in relay
– RDZ101ZB: With wireless output module
Open window detection
●
●
●
Frost protection
Schedule via mobile application "Connected Home" (downloadable from
Google Play™ or Apple App Store®)
●
●
Adjustable commissioning and control parameters via mobile application
Battery-powered (2xAA batteries)
A6V13360592_en--_c
2023-10-09
Siemens AG
Smart Infrastructure
| General | Details |
|---|---|
| Name | SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual |
| Make | SIEMENS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.36 MB |

SIEMENS RDG400 Room Thermostat Instruction Manual

SIEMENS M3182 Room Thermostat Instruction Manual

SIEMENS RDS120-B Smart Thermostat Instructions

SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual

SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual

SIEMENS RDH100RF/SET Room Thermostat Instruction Manual

SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide

SIEMENS RS485 Flush Mounted Room Thermostat User Manual

SIEMENS RDG260KN Room Thermostat Instruction Manual

SIEMENS RDF660MB Flush Mount Room Thermostat Instruction Manual

SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: Zigbee room thermostat, wired and wireless, battery powered. For heating systems. Room temperature control. Communicates with Connected Home Hub via Zigbee network. 2-position/TPI control with On/Off output for heating. Open window detection. Frost protection. Schedule via mobile application Connected Home. Adjustable commissioning and control parameters via mobile application. Battery-powered (2xAA batteries).
- Page 2: The RDZ100ZB/RDZ101ZB is part of Siemens Connected Home ecosystem. It is used to control the room temperature in heating systems. Typical applications include apartments and single-family homes. It controls thermal valves, gas or oil boilers, heat pumps, circulating pumps, and floor heating. Functions include room temperature control via a built-in sensor, selection of operating mode, setting schedule via the mobile application, and display of current room temperature. Additional features are setpoint override, limitation of minimum/maximum setpoint adjustments, remote operation and monitoring, open window detection, and valve exercising. It supports heat demand-based boiler or pump release in combination with Connected Home receiver RCR110.2ZB. The device allows for factory reset, wireless communication, firmware upgrade via Zigbee, and has an auto sleep function to save battery. Type summary includes RDZ100ZB, RDZ101ZB, and RCR110.2ZB with their respective stock numbers. Accessories include the ARG101 Italian adapter plate for RDZ100ZB and RDZ101ZB. RCR110.2ZB and ARG101 are not included in the delivery and must be ordered separately.
- Page 3: RDZ100ZB mounting plate RDZ100ZB front panel Battery Mounting instructions RDZ101ZB mounting plate RDZ101ZB table stand RDZ101ZB front panel Equipment combinations Type of unit Use with the type of temperature control
- Page 4: Product documentation includes various titles and document IDs. Mounting instructions and operation manual are essential components. CE and UKCA declarations are part of the documentation. Environmental declarations are also included. Safety is a critical section with specific cautions and warnings. Compliance with national safety regulations is necessary to prevent injury and property damage. Warnings address risks such as explosion, fire, and short-circuit. Batteries must not come into contact with water or be recharged. Damaged batteries should be handled with protective gloves to avoid chemical burns. Immediate medical attention is required if electrolyte contacts the eyes.
- Page 5: Mounting RDZ100ZB is suitable for wall mounting. RDZ101ZB is suitable for wall mounting and table standing. Recommended height for wall mounting: 1.50 m above the floor. Mount the thermostat close to Connected Home Hub if possible. Do not mount or place the thermostat in recesses, behind curtains or doors, or above or near heat sources. Do not mount or place the thermostat near large metal structures or other construction elements with fine metal meshes. Do not mount or place the thermostat in a location where it is exposed to dripping water, moisture or excessive heat. Avoid placing RDZ101ZB inside or near metal or sources of radio or electromagnetic energy or interference. Seal the conduit box or the installation tube if any, as air currents can affect sensor readings. Make sure wiring, protection, and earthing comply with local regulations.
- Page 6: Installation No internal line protection for supply lines to external consumers poses a risk of fire and injury due to short-circuits. Adapt the line diameters as per local regulations to the rated value of the installed fuse. Risk of explosion can lead to personal injury and property damage. Insert the battery at the correct polarity (+/-) using the illustration in the battery compartment. Insert only the correct battery types according to the indication in the battery compartment. Store, transport and dispose of the batteries in compliance with local requirements, regulations and laws. The batteries must be undamaged. Do not mix new and used batteries. The thermostat is ready for commissioning after batteries are inserted. After joining is initiated from the mobile application, tap and hold for more than five seconds on the thermostat to join the Zigbee network.
- Page 7: Open Source Software (OSS) These devices use Open Source Software (OSS). All Open Source Software components used in the product are available. Disposal This symbol indicates that the product, its packaging, and any batteries may not be disposed of as domestic waste. Delete all personal data and dispose of the items at separate collection and recycling facilities. Warranty Technical data on specific applications are valid only with Siemens products listed under Equipment combinations. Siemens rejects any and all warranties if third-party products are used.
- Page 8: General technical data Power supply Operating voltage Battery life DC 3 V (2 x 1.5 V AA alkaline batteries) 1 year Radio parameters Frequency band 2.4…2.4835 GHz Maximum radio-frequency power Communication standard Based on Zigbee 3.0 Protection mode Built-in room temperature sensor Setpoint setting range Accuracy at 25 °C Degree of protection of housing as per EN 60529 Protection against electrical shock
- Page 9: Ambient conditions and protection classification Overvoltage category Rated impulse voltage Climatic ambient conditions Transport and storage (in packaging) Operation (in dry locations having no temperature or humidity control) Mechanical ambient conditions Standards, directives and approvals Environmental compatibility General
- Page 10: General Thermostat RDZ100ZB and RDZ101ZB specifications. Technical data for RDZ100ZB includes switching capacity of relay, voltage, and current. AC voltage range is 24 to 230 V. Maximum current for Lx - L1 and Lx - L2 is 5 A. Warning: No internal fuse; external protection with a maximum C 10 A circuit breaker is required. External protection for incoming cable must include a circuit breaker with a maximum of 10 A. Circuit breaker tripping characteristic should be Type B, C, or D as per EN 60898 and EN 60947. Contact life at AC 230 V at 5 A resistive load is guided at 1 x 10^5 cycles. Electrical connections use screw terminals for solid or prepared stranded wires. Connection specifications include 2 x 1.5 mm² or 1 x 2.5 mm² (minimum 0.5 mm²).
- Page 11: Connection diagrams Live, AC 24...230 V Neutral conductor, AC 24...230 V Wired room thermostat RDZ100ZB Actuating device Current higher than 5(2) A is not allowed to go through RDZ100ZB controller. For high current device, an additional relay or contactor must be installed. Wireless room thermostat RDZ101ZB Wireless output module RCR110.2ZB Neutral conductor, AC 230 V
- Page 12: Application examples Gas boiler Floor heating with valve Radiator with pump Electric boiler Electric radiator Heat generator (for example, boiler) Magnetic valve Circulating pump Siemens Smart Infrastructure
- Page 13: Dimensions Regulatory compliance information Radio equipment directive The equipment uses harmonized frequency in Europe and complies with Radio Equipment Directive 2014/53/EU.