Home > SAVANT > SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide

SAVANT CLI-W220X-00 Multistat Smart Thermostat User Guide

HVAC Wiring  
Use the table below when making connections between the thermostat and an HVAC system. The type of HVAC  
system installed determines which wires are connected and in some installations, the power wires are the only wires  
required.  
Relay to control changeover valve on a Heat  
Pump  
O
HELPFUL!  
G
Fan Relay  
Refer to the Making Connections section  
above to ensure a safe and secure connection  
is made.  
Y2  
Y1  
Relay for control of 2nd stage cooling  
Relay for control of 1st stage cooling  
Relay for control of 2nd stage heating  
Relay for control of 1st stage heating  
Additional information on the terminal desig-  
nators and how to wire the thermostat into dif-  
ferent types of HVAC systems is available in the  
Multistat Smart Thermostat Deployment Guide  
located on the Savant Customer Community.  
W2  
W1  
Remote Sensors  
GE Wireless Bluetooth Temperature Sensor  
Included in the box is an external Bluetooth Low Energy (BLE) temperature flush mount wireless sensor. This sensor  
is used in place of an internal temperature sensor, allowing for optimal sensor placement to achieve more accurate  
temperature readings. The sensor must be placed within Bluetooth range of the thermostat, up to 25 feet in open air.  
Note that signal interference or material obstruction may reduce this effective range.  
See the GE Wireless Bluetooth Temperature Sensor (93129901)  
QRG (009-2091-xx) for more information on this sensor.  
The GE Wireless Bluetooth Temperature Sensor may be installed  
with a screw and anchor into a wall, or with the provided adhesive  
strip. If using the adhesive strip, record the 6-digit pin number on  
the back. This number will be used during app configuration.  
000000  
Up to six (6) GE Wireless Bluetooth Temperatures Sensors can be  
connected to a CLI-W220 at a time.  
Back  
Front  
Optional 10K Type Sensors  
The CLI-W220x includes two thermistor ports labeled RS1 and RS2 for 10KΩ type temperature sensors. Like the  
Bluetooth temperature sensor described above, this sensor can replace the onboard temperature sensor or can be  
used to calculate an average reading of the temperature in a room or space. The 10K sensors do NOT observe any  
polarity. Refer to the diagram below when making connections for 10K type sensors or thermistors.  
Savant offers a range of 10KΩ type sensors that are compatible with  
the CLI-W220x, including:  
Remote Sensor  
SST-TEMP1-xx Flush Mount Remote Sensor (QRG: 009-0800-xx)  
CLI-THFM1-xx Temperature/Humidity Sensor QRG: 009-1064-xx)  
SST-OTEMP-xx Outdoor Remote Sensor (QRG: 009-0989-xx)  
CLI-PLEN1R/C-xx Plenum Sensor (QRG: 009-1096-xx)  
CLI-SLAB1-xx SLAB Sensor (QRG: 009-1097-xx)  
Multistat Smart Thermostat Quick Start Guide | 009-2428-01  
4
of  
8
45 Perseverance Way, Hyannis MA 02601  
Savant.com | 508.683.2500  
Copyright ©2025 Savant Systems, Inc  
|