Home > Pro > PRO T755 Universal Thermostat Installation Guide

PRO T755 Universal Thermostat Installation Guide

Tech Settings  
Tech Settings  
Tech Settings  
Tech Settings  
LCD Will Show Adjustment Options Default  
LCD Will Show Adjustment Options Default  
This feature allows you to put  
If selected ON, you will see  
the input screen after  
pressing NEXT STEP. Use the  
or button to select  
the desired number and  
the FAN or SYSTEM key to  
move from one character to  
another. See note below for  
operation.  
Enables the use of up to sixteen  
You can use 1, 4, 9, or 16  
Number  
of Indoor  
Remotes  
indoor sensors. Refer to the  
R251S Install Manual for de-  
tailed connection information  
your phone number in the  
display. You can choose ON or  
OFF.  
indoor sensors R251S. Note: Will  
only show Remote Sensor is set  
to 1 and Local Temp Sensor is  
set to on.  
Notes:  
1
1
If contractor call number is selected  
ON, the phone number entered will  
show in the display if there has been a  
continuous call for heating or cooling  
for 24 hours or if the light button is  
held down for 3 seconds. To remove  
the phone number from the display,  
hold the light button down for 3  
seconds.  
(Only displayed  
if remote sensor  
setting is set to 1)  
Contractor  
Call Number  
OF  
OFF  
NUMBER REMOTE  
An outdoor temperature above  
balance point will cause the  
thermostat to energize the Y  
terminal(s) only in calls for heat.  
An outdoor temperature below  
balance point will cause the  
thermostat to energize the W2  
terminal only in calls for heat.  
Use the and buttons  
to select OFF, 10, 15, 20, 25,  
30, 35, 40, 45, 50 degrees.  
Dual Fuel  
Balance  
Point  
PHONE NUMBER  
(Only displayed  
if remote sensor  
setting is set to  
2 and Dual Fuel  
AUX = On)  
OF  
OFF  
You can configure the thermostat  
for one of three remote sensor  
applications: 0 No Sensor, 1  
Indoor, 2 Outdoor, 3 Floor.  
Remote  
Sensor  
Operation  
Use the left and right  
arrows to select one of  
three options. View the S1/  
S2 terminal chart on next  
page for an explanation of  
these options.  
BALANCE POINT  
(Only displayed  
if a sensor is  
connected  
to S1 and S2  
terminals)  
0
0
REMOTE MODE  
S1 / S2 Terminal  
Description  
You can disable the sensor on  
the T855SH thermostat. At least  
one R251S indoor remote sensor  
must be connected to disable the  
local T855S sensor. Note: Will only  
show if remote sensor is set to 1.  
ON enables local T855SH  
sensor. OFF disables local  
T855SH sensor.  
Options Mode  
Requires  
Local Temp  
Sensor  
The local and remote temperatures are averaged.  
The outdoor temperature is flashed in clock.  
The floor temperature is shown in tech.  
1
2
3
Indoor  
Outdoor  
Floor  
R251S  
R250S  
R250S  
ON  
(Only displayed  
if remote sensor  
setting is set to 1)  
LOCAL TEMP  
18  
17  
Tech Settings  
Programming  
Set Time  
Tech Settings  
LCD Will Show Adjustment Options Default  
Balance point run time will allow  
Off, 15, 30, 45, 60, 75, 90  
1. With system switch set to OFF, press the MENU button  
2. Press SET TIME  
the W2 auxiliary terminal to ener-  
gize even if outdoor temperature  
is above selected balance point  
temperature. If enabled, auxiliary  
will energize for the current cycle  
after the balance point run time  
has expired.  
Balance  
Point Run  
Time  
3. Day of the week will be flashing. Use the  
to select the current day of the week.  
4. Press NEXT STEP  
or  
key  
(Only displayed  
if remote sensor  
setting is set  
to 2)  
OF  
OFF  
5. The current hour is flashing. Use the  
or  
key to  
Note: Only shows if Balance Point is  
set to an outdoor temperature.  
select the current hour. When using 12-hour time, make sure  
the correct a.m. or p.m. choice is selected.  
6. Press NEXT STEP  
BP RUN TIME  
The temperature of the floor  
sensor will be displayed.  
N/A  
7. Minutes are now flashing. Use the  
select current minutes.  
8. Press DONE when completed.  
or  
key to  
Floor  
Temperature  
Note: Only shows when REOP is  
set to 3.  
76  
N/A  
(Only displayed  
if remote sensor  
Use and buttons to adjust.  
Programming  
setting is set to 3)  
FLOOR TEMP  
All of our programmable thermostats are shipped with an  
energy saving pre-program. You can customize this default  
program by following the steps on the next page.  
This setting allows you to set  
a maximum floor temperature  
limit for heat. Heat will be locked  
out when the floor temperature  
is above this value. Note: Only  
shows when REOP is set to 3.  
Use the or buttons to  
select the High Limit for the  
floor sensor.35 - 120  
Floor High  
Limit  
There are four time periods for each program (WAKE, LEAVE,  
RETURN, SLEEP).  
86  
(Only displayed  
if remote sensor  
setting is set  
to 3)  
86  
HIGH LIMIT  
A Note About Auto Changeover:  
This setting allows you to set  
a minimum floor temperature  
limit for heat. Heat will turn on  
automatically when the floor  
temperature is below this value.  
Note: Only shows when REOP is  
set to 3.  
Use the or keys to  
select the Low Limit for the  
floor sensor.  
In Auto you have the ability to switch between Auto Heat or Auto Cool  
by pressing the system key. This can be done once the current mode has  
reached its setpoint. For example: if in Auto Heat, the heat setpoint must  
be satisfied before the thermostat will allow you to switch to Auto Cool.  
You can switch out of Auto by holding down the system key. To get back  
into Auto, you must toggle the system key to Auto.  
Floor Low  
Limit  
35 - 120  
50  
(Only displayed  
if remote sensor  
setting is set to 3)  
50  
LOW LIMIT  
20  
19  
GeneralDetails
NamePRO T755 Universal Thermostat Installation Guide
MakePro
LanguageEnglish
FiletypePDF (Download)
File size0.43 MB
Download PDF