Programming  
Programming  
Programming  
Set Program Schedule 5+1+1 or 7 Day  
To customize your program schedule, follow these steps:  
All of our programmable thermostats are shipped with an  
energy saving pre-program. You can customize this default  
program by following the steps on page 16.  
1. Select HEAT or COOL with the system switch. Note: You have  
to program heat and cool each seperately.  
There are four time periods for each program (WAKE, LEAVE,  
RETURN, SLEEP).  
2. Press the MENU button (If menu does not appear first press RUN SCHED)  
3. Press SET SCHED. Note: Monday-Friday or (Monday if in 7 Day)  
is displayed and the WAKE icon is shown. You are now  
programming the wake time period for that day.  
4. Time is flashing. Use the  
or  
key to make your time  
selection for that day’s WAKE time period. Note: If you want  
the fan to run continuously during this time period, select ON  
with the FAN key  
5. Press NEXT STEP  
6. The setpoint temperature is flashing. Use the  
to make your setpoint selection for that day’s WAKE time  
or  
key  
period.  
7. Press NEXT STEP  
8. Repeat steps 4 thru 7 for that day’s LEAVE time period,  
RETURN time period, and SLEEP time period.  
If in 5+1+1 Programming:  
Repeat steps 4 thru 8 for the Saturday + Sunday time  
periods.  
If using 7- Day Programming:  
Use these same steps for every individual day.  
22  
21  
Programming  
Specifications  
Specifications  
You can use the table below to plan your customized program schedule.  
The display range of temperature ... 41˚F to 95˚F (5˚C to 35˚C)  
The control range of temperature.... 44˚F to 90˚F (7˚C to 32˚C)  
Load Rating............................................... 1 amp per terminal, 1.5 amp  
maximum all terminals combined  
Swing (cycle rate or differential) ...... Heating is adjustable from 0.2˚ to 2.0˚  
Cooling is adjustable from 0.2˚ to 2.0˚  
Power source ...........................................18 to 30 VAC, NEC Class II, 50/60 Hz  
for hardwire  
Battery power from 2 AA Alkaline  
batteries  
Operating ambient ............................... 32˚F to +105˚F (0˚C to +41˚C)  
Operating humidity .............................. 90% non-condensing maximum  
Dimensions of thermostat ................. 4.7”W x 4.3H x 0.9D  
23  
24  
GeneralDetails
NamePRO T755 Universal Thermostat Installation Guide
MakePro
LanguageEnglish
FiletypePDF (Download)
File size0.43 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
PRO T751 Thermostat Installation Guide
PRO T751 Thermostat Installation Guide

PRO T755 Universal Thermostat Installation Guide