Left button:  
Push right button in main screen to go straight to Menu settings (2.4)  
Confirming a choice  
2.Temporary temperature:  
To temporarily override the temperature in the automatic  
program. The override will operate until the next automatic event.  
Select an option  
(
)
Right button:  
3.Manual mode:  
Push left button in main screen to go straight to Mode functions (2.3)  
To get back to last screen or main screen(← or X )  
The thermostat runs continuously according to the set temperature.  
USER MANUAL  
Always go back to the main screen after making changes.  
4.OFF:  
Explanation of LED colours / signals :  
Manually turn off all functions of the thermostat. When you want to reactivate  
the thermostat, just select the mode you want.  
Heating  
Red:  
System operation(standard or Costum)  
Green:  
Installation  
Red light flashing on and off: Sensor fault  
5.Anti-frost mode:  
1.Check if the power is off. Remove the display frame by pushing a non sharp  
instrument (for example the point of a ballpoint pen) carefully in the square hole  
underneath the thermostat.  
Range is set from 41°F to 59°F(5°C -15°Cin this mode. This mode is used  
when you want to keep your room at a lower temperature when you are on  
vacation.  
2.Connection schedule:  
L/N lead : Connect the power cord using the terminal block.  
L1/N1 lead : Use a terminal block to connect the load line(Max 16A).  
S1/COM/ : Connect the floor sensor.  
Pilot : Connect the pilot to L when the pilot wire function needs to be enabled.  
WARNINGS: 1.Disconnect the main power supply before wiring.  
Installation needs to be done by a qualified electrician in accordance with  
all current wiring and building regulations. 2.Electric floor heating cable/  
mat must be in accordance with the supply voltage.The terminals are  
designed to handle a cross-section of wire measuring 12-22AWG.  
6.Timer:  
Date  
Time  
Use this mode when you are on holidays etc.The thermostat will be off for the  
chosen period. After this period, the thermostat will return to the standard or  
the custom time settings.  
Measured Temp  
Mode  
Menu  
7.Slow heating:  
Menu/Confirm  
LED  
To be used for new floors only. The thermostat will slowly raise the  
temperature of the floor over a 20 day period. After this period the thermostat  
automatically starts the standard or the custom time programme. If you need  
to stop or restart the slow start up mode, press the left button.  
Mode/get back  
3.The display frame and the cover frame can be removed. Position the  
thermostat and install onto the back box (not supplied). Place the display frame  
back into position by pushing it softly.  
Up/Down/Scroll  
Menu selection  
1.Temperature settings:  
POWER  
You can change the programmed temperature (comfort or set back ).  
Attention: In the case of floor heating, it is not necessary to program  
the setback temperature.The setback temperature is controlled by the  
thermostat automatically.  
Start up wizard  
Language  
Date  
1
2
Units  
3
-year;  
program the current year.  
-make your language choice.  
This is the first question in the  
start up menu.  
- Clock;  
choose 12 or 24 hour clock  
time (am/pm) .  
01  
02  
2.Programming:  
The comfort temperature and times can be changed in this menu.  
Standard program:  
-month;  
program the current month.  
- Temperature;  
choose °C or °F scale .  
-day number;  
program the current day.  
Monday--Sunday  
Period 1  
Period 2  
06:00-09:00 23℃  
17:00-22:00 23℃  
Time  
Intelligence  
Heating system  
4
5
6
Custom week program: Push the button to confirm the function ‘program’.  
You enter the screen with the standard settings schedule.  
-Floor heating or different  
heating system. If you choose  
a different heating system the  
question will be whether the  
system needs to function on  
the internal room sensor or  
external sensor.  
-program time;  
program the actual clock time  
-This function enables the  
thermostat to calculate when  
it needs to switch on so that  
the required temperature is  
reached at the set time.  
04  
03  
Press  
Press  
Press  
Press  
button,‘standard’ appears on the display.  
button,‘standard’ is selected.  
button select ‘custom’. confirm this with  
button.  
/
button return to the screen of programmed times.  
Note:  
Now you can confirm the symbol by pushing the right button.  
You can adjust one or two periods a day. If you want to program the same time  
periods on different days, use the easy copy and paste function.  
According to user preference,  
the circular and square outer  
frame can be replaced.  
Summary  
Surface material  
Temp.to control  
9
7
8
-If you choose floor heating.  
Wood or other. If you choose  
other, the question is asked if  
there is a floor sensor installed  
-Containing the current  
settings.  
-Floor or room sensor.  
05  
3.Consumption:  
If you choose floor heating,  
we advise you to control the  
floor temperature by using  
the floor sensor.  
The thermostat calculates the average time it has been switched on allowing  
you to monitor your energy consumption. The total switched on time is by  
percentage (%) shown over the last 30 and 365 days.  
Calculate consumption:  
30 days: 24 hours x 30 days x total installed power x % = energy consumption  
365 days: 24 hours x 365 days x total installed power x % = energy consumption  
Example:  
The thermostat gives a percentage of 26% over 30days.  
The power installed in the floor is 700 Watt.  
24 hours x 30 days = 720 hours.  
720 hours x 0.7 kW = 504 kWh  
26% of 504 kWh = 131 kWh.  
Supply voltage:  
Load:  
85-265 VAC 50/60 Hz  
max.16 A (resistive load)  
11 Overview wizard  
Slow heating  
Temperature  
12  
10  
-Containing the selected  
heating periods according the  
standard program.  
-It is possible to choose this  
option (Ref Mode selection  
point 7 slow start up).  
-Program the comfort temp-  
erature of your choice for a  
heating period. Standard  
temperature for a “different  
heating system is program-  
med at 21 degree Celsius and  
23 degree Celcius for a floor  
heating system.  
Setpoint range:  
Temperature range:  
Cover:  
+5 to +40°C / +41 to +104°F  
+5 to +45°C / +41 to +113°F  
IP21  
Approvals:  
CE/UKCA  
Floor sensor type:  
NTC B=3740 12k  
4.Child lock:  
The thermostat is locked with this function.Mode and menu settings cannot  
be used.To switch the child lock function on or off, push the right key and  
hold it for a few seconds. When the child lock is switched on, a padlock  
appears on the display.  
Operation and LED  
Keys operation:  
Mode selection  
5.Information:  
1.Automatic mode:  
Middle buttons:  
Gives information about the current software and hardware version of the  
thermostat.  
Adjustment up and down (±o
To scroll through settings  
)
According to the weekly program, the thermostat automatically adjusts the  
set temperature operation.  
GeneralDetails
NameKlima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual
Makeklima
LanguageEnglish
FiletypePDF (Download)
File size0.5 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
klima SF300 Thermostat User Manual
klima SF300 Thermostat User Manual
Klima 825200 Electric Underfloor Heating Thermostat User Manual
Klima 825200 Electric Underfloor Heating Thermostat User Manual
Klima C16 WiFi Floor Heating Thermostat User Guide
Klima C16 WiFi Floor Heating Thermostat User Guide
Klima H001 Smart Thermostat For Air Conditioner User Manual
Klima H001 Smart Thermostat For Air Conditioner User Manual
Klima SF300 Digital Thermostat Instruction Manual
Klima SF300 Digital Thermostat Instruction Manual

Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual
Get the free PDF manual for the Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Klima 825201 Intelligent Control Wi-Fi Underfloor Heating Thermostat User Manual Overview

Summary of Contents

  • Page 1: Left button: Push right button in main screen to go straight to Menu settings. Temporary temperature: To temporarily override the temperature in the automatic program. Manual mode: The thermostat runs continuously according to the set temperature. OFF: Manually turn off all functions of the thermostat. Anti-frost mode: Range is set from 41°F to 59°F in this mode. Timer: Use this mode when you are on holidays; the thermostat will be off for the chosen period. Slow heating: The thermostat will slowly raise the temperature of the floor over a 20-day period. Programming: The comfort temperature and times can be changed in this menu. Consumption: The thermostat calculates the average time it has been switched on allowing you to monitor your energy consumption. Child lock: The thermostat is locked with this function; mode and menu settings cannot be used.
  • Page 2: If you are in the process of networking, the device cannot be discovered. You can press + and - buttons on the thermostat at the same time to switch the wifi connection mode. With this function you can change settings related with the operating of the thermostat. The thermostat will change summer and winter clock change automatically. The thermostat provides advanced settings to suit a range of special situations which are normally set by a technician during initial installation. The thermostat has a self thinking and adaptive system. This function only works when room sensor or both sensors is selected. All parameters are restored to default value. The setback mode is when the thermostat ‘sets back’ to a lower temperature during the off time periods. Some floor coverings must be limited at a certain maximum temperature.