JUNG RTR230 230V Room Thermostat User Manual
Room thermostat (1-way NC contact) 230 V
–
Valve protection function (once a week opening and closing of valve)
5
Operation
Increasing or reducing the room temperature
■
Turn the control knob to the right or left.
In the middle position, the device regulates to approx. 20 °C setpoint temperature. The
room temperature reached depends on the installation location of the device and the am-
bient conditions. The lowest setpoint temperature is approx. 5 °C and the highest setpoint
temperature is approx. 30 °C
6
Information for electrically skilled persons
Selecting a suitable installation location
–
–
Recommended installation height: 1.50 m on interior walls
Do not mount the device near sources of interference, such as ovens, refrigerators,
draughts (e.g. next to the door) or direct sunlight. This affects the temperature measure-
ment of the internal temperature sensor.
–
–
Do not mount the device within shelf walls or behind curtains and similar covers
Do not use the device in multiple combinations with heat-generating devices such as dim-
mers
DANGER!
Mortal danger of electric shock.
Disconnect the device. Cover up live parts.
Connecting and fitting the device
Figure 2: Connection example of the insert
82404803
J0082404803
05.05.2022
2 / 4
| General | Details |
|---|---|
| Name | JUNG RTR230 230V Room Thermostat User Manual |
| Make | JUNG |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.09 MB |

Jung FTR231 Floor Thermostat Instruction Manual