Pull the control knob off the central plate so that the adjustment rings are vis-
ible Bild.
Pulling off is done by hand or with a suitable tool, e.g. vacuum lifting tool or
key cap puller.
■
■
Turn the large blue adjustment ring clockwise to the desired minimum temper-
ature. Each notch corresponds to a change of about 2 °C.
Turn the small red adjustment ring anticlockwise to the desired maximum tem-
perature.
The respective adjustment ring can only be turned in one direction. To return
to the original setting, continue turning to the respective position.
■
Replace the control knob, observing the coding (Fig. 4, bottom) of the control
knob and rotary axle.
8
Technical data
Rated voltage
Mains frequency
Switching current
AC 220 ... 240 V ~
50 / 60 Hz
10 A
Connected load
Ohmic load
Standby power
2300 W
max. 0.15 W
-5 ... +45 °C
-25 ... +70 °C
max. 100 m
IV
Ambient temperature
Storage/transport temperature
Cable length inputs
Controller class (EU 811/2013)
Contribution to energy efficiency
2%
FFNTC remote sensor
Dimensions Ø×H
Length connecting cable
Degree of protection
7.8 × 28 mm
4 m (can be extended to 50 m)
IP 67
Remote sensor resistance values
Temperature
(°C)
Resistance
Temperature
Resistance
(kΩ)
(kΩ)
(°C)
5
89.5
68.8
53.5
41.9
33.0
30
35
40
45
50
26.2
20.9
16.7
13.5
11.0
10
15
20
25
82404923