Floor thermostat  
Image 2: Connection example of the insert  
Image 3: Clampable conductor cross-section  
(7)  
(8)  
(9)  
External temperature sensor (remote sensor)  
Switching contact of central clock  
Electric underfloor heating  
Connect insert (1) according to the connection diagram (see figure 2). Ob-  
serve the conductor cross-sections (see figure 3).  
Optionally, connect the ECO operation input Ø via a switching contact of a  
central clock (8).  
If 230 V is applied to the input, the target temperature is reduced by 4 °C.  
Fit device in appliance box; terminals must be at the bottom.  
Fit the frame, central plate and control knob.  
Switch on mains voltage.  
7.1  
Commissioning  
Setting control behaviour  
Factory setting: pulse width modulated control (PWM)  
82404923  
7 / 10  
29.11.2022  
J0082404923  
     