Hotwire Heating HWGL2 Dual Device Thermostat Instruction Manual

HotwireThermostat  
Technical Information  
Configuration Menu  
To enter into the setting menu please follow the steps below:  
Step 1. Turn the thermostat off by pressing  
HotwireThermostat  
Instructions  
Step 2. Press  
you will then see menu 1.(Press and hold  
for about 5 seconds, you will see menu 12)  
Step 3. Use the increase and decrease arrows to adjust the sensor selection which is Menu 1(Air sensing;Air and Floor, or Floor only)  
Step 4. Press  
to move to the next Menu and once you have all the menu options set,  
press  
to accept and store.  
Adjustment  
Feature  
Explanation  
Menu #  
Model Number: HWGL2 Dual Device Thermostat  
(Press up & down buttons to adjust)  
This thermostat is a combination model which allows you  
to choose 3 different modes.  
A / AF / F  
1
2
Mode/Sensor Selection  
A mode = Air Sensing Only(Has built in sensor)  
AF mode = Air & Floor sensing (Floor probe must be installed)  
F mode = Floor Sensing(Floor probe must be installed)  
The number of degrees difference before switching.  
The default is 1°C which means the thermostat will switch  
the heating on 0.5°C below the set temperature and will turn  
it off 0.5°C above the set temperature.With a 2°C differential  
the heating will switch on 1°C below the set temperature  
and will switch off 1°C above the set temperature.  
Switching differential  
1 Deg C, 2 Deg C....10 Deg C ( 1 Deg C by default)  
-1 Deg C = decrease 1 °C , 1 Deg C = increase 1  
Deg C  
3
4
Air Temp Calibration  
This is to recalibrate the air temp if required  
-1 Deg C = decrease 1 °C , 1 Deg C = increase 1  
Deg C  
Floor Temp Calibration  
This is to recalibrate the floor temperature if required  
A = Show Air Temperature  
F = Show Floor Temperature  
A-F = Show Floor and Air Temperature in 5 sec  
intervals  
Temperature Readout  
(AF mode only)  
This gives you the option to show the Air Temp,  
Floor Temp or to show both Air & Floor at intervals  
5
Maximum Floor Temp  
( AF Mode only)  
6
7
8
This is to protect the floor surface  
20 Deg C - 40 Deg C (40 Deg C by default)  
Deg C / Deg F  
This allows the temperature to be set to show  
Deg Celsius or Deg Fahrenheit  
Temperature Format  
Frost Protection  
This is to avoid your room temp going below 5 DegC  
On = activated, Off = deactivated  
This allows you to programme either 5 days at once,  
then the 2 days of the weekend separately,  
or a full 7 days at the same time or 7 days separately.  
01 = 5 + 2 Day Programming  
02 = 7 Day Programming  
5+2 / 7 Day mode  
9
Auto/Manual mode  
selection  
00 = Auto mode  
01 = Manual mode  
10  
This allows you to choose Auto / Manual mode  
11  
12  
Software version  
This is for review only  
V1.0  
Minimum temperature  
This gives you the option to change the minimum set  
temperature  
5 °C~ 20 °C (5 °C by default)  
40 °C~ 90 °C (40 °C by default)  
limit  
Maximum temperature  
limit  
This gives you the option to change the maximum set  
temperature  
13  
14  
10 = NTC10K(by default), 100= NTC100K,  
3=NTC3K  
Sensor type selection  
This allows you to match your thermostat to different sensor  
10%~100%  
100 = 100%(by default)  
This allows you to adjust the brightness of the back light  
This allows you to reset your thermostat to factory default  
This allows you to choose to install your thermostat vertically or horizontally  
AUSTRALIA NEW ZEALAND  
Hotwire Heating The Heating Company  
15  
16  
17  
Backlit brightness  
Reset  
Press and hold down button until you see RE on screen  
L = Vertical H= horizontal  
Direction of installation  
GeneralDetails
NameHotwire Heating HWGL2 Dual Device Thermostat Instruction Manual
MakeHotwire Heating
LanguageEnglish
FiletypePDF (Download)
File size0.32 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Hotwire Heating HWGL2 Dual Device Thermostat Instruction Manual
Get the free PDF manual for the Hotwire Heating HWGL2 Dual Device Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Hotwire Heating HWGL2 Dual Device Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Hotwire thermostat technical information To enter into the setting menu, turn the thermostat off and follow the steps. Menu options include air sensing, air and floor sensing, or floor only. The thermostat allows for three different modes: A, AF, and F. Switching differential can be set between 1°C and 10°C, with 1°C as the default. Air temperature calibration allows for adjustments in 1°C increments. Floor temperature calibration is also adjustable in 1°C increments. Temperature readout options include air temperature, floor temperature, or both. Frost protection prevents room temperature from dropping below 5°C. Programming options include 5+2 day programming or 7-day programming. Minimum and maximum temperature limits can be set between 5°C to 20°C and 40°C to 90°C, respectively.
  • Page 2: Programming your thermostat will help you set it to come on and off automatically. When programming Zone 2 for your heated towel rail, set the time only and select “On” for options 1 and 3, and “Off” for options 2 and 4. The thermostat is a dual control model that can be switched between manual and auto mode. In manual mode, the thermostat maintains a constant set temperature manually set by the user. In auto mode, the thermostat executes the preprogrammed schedules. To lock the keypad, press and hold the power button for 5 seconds. This manual outlines how to program the unit, and a step-by-step video is available for assistance. The thermostat has a real-time clock that must be set accurately for programmed events to start on time. This thermostat can program each individual day of the week separately or program 7 days at once. If you do not require heating in the afternoon/evening, set the off time a couple of minutes after the on time.