Round™ Smart Thermostat  
TH8732WFH5004  
Professional Install Guide  
System Types  
72  
Compatible with 24-volt systems such as forced air, hydronic, heat pump (including dual fuel),  
oil, gas and electric.  
Does not work with electric baseboard heat (120/240V).  
Mercury Notice:  
If this product is replacing a control that contains mercury in a sealed tube, do not place the  
old control in the trash. Contact the Thermostat Recycling Corporation at 1-800-238-8192 or  
thermostat-recycle.org for information on how and where to properly and safely dispose an old  
thermostat.  
Search for local rebates:  
Disconnect power before installation.  
HoneywellHome.com/Rebates  
Can cause electrical shock or equipment damage.  
Must be installed by a trained, experienced technician  
Read these instructions carefully. Failure to follow these instructions can  
damage the product or cause a hazardous condition.  
3
Connect wires and mount wallplate  
Installation  
Connect wires and mount the wall  
plate using screws and anchors  
provided.  
1
Set Jumper Switches  
R Jumper Switch:  
Note: The illustration to the right  
shows the most common wiring.  
For single  
For dual  
transformer  
systems, move  
switch up.  
transformer  
systems, move  
switch down.  
REQUIRED: A C-Wire (common wire)  
is needed for 24 VAC power.  
Electrical Ratings:  
Terminal  
Voltage (50/60 Hz)  
18 to 30 VAC  
18 to 30 VAC  
18 to 30 VAC  
18 to 30 VAC  
18 to 30 VAC  
18 to 30 VAC  
18 to 30 VAC  
18 to 30 VAC  
Max. Current Rating  
1.00 A  
Jumper Switch for humidifier, dehumidifier, or ventilation:  
W - O/B (Heating)  
W2 - Aux/E (Heating)  
Y (Cooling)  
Y2 (Cooling)  
K
0.60 A  
1.00 A  
For single wire  
products, set  
the switch to 1  
Wire.  
For two wire  
products,  
0.60 A  
1.00 A  
set the switch to  
2 Wire.  
G (Fan)  
0.50 A  
L (Output)  
U1, U2  
1.00 A  
0.40 A  
2
Wiring: Terminal Designations  
L
C
Heat pump system monitor  
K
G
Optional C-wire adaptor  
Common wire from secondary  
side of cooling transformer, if 2  
transformers  
Fan relay  
4
Firmly snap the thermostat into  
place  
The thermostat will glow and  
display the screen for up to three  
minutes while it starts up.  
W2  
(AUX) auxiliary, emergency heat)  
1st stage heat relay (changeover  
(O/B) valve for heat pumps)  
2nd stage heat relay (heat pump  
Y2  
Y
2nd stage compressor  
contactor  
W
1st stage compressor  
contactor  
U1  
Terminal for indoor air quality  
R
Heating power. Connect to  
secondary side of heating  
system transformer  
products (humidifier, dehumidifier,  
ventilator)  
U2  
Terminal for indoor air quality  
products (humidifier, dehumidifier,  
ventilator)  
Rc  
Cooling power. Connect to  
secondary side of cooling  
system transformer  
GeneralDetails
NameHoneywell TH8732WFH5004 Round Smart Thermostat User Guide
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell Lyric T5 Wi-Fi Thermostat Installation Guide
Honeywell Lyric T5 Wi-Fi Thermostat Installation Guide

Honeywell TH8732WFH5004 Round Smart Thermostat User Guide
Get the free PDF manual for the Honeywell TH8732WFH5004 Round Smart Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Honeywell TH8732WFH5004 Round Smart Thermostat User Guide Overview

Summary of Contents

  • Page 1: Round Smart Thermostat TH8732WFH5004 Professional Install Guide Compatible with 24-volt systems such as forced air, hydronic, heat pump, oil, gas, and electric. Does not work with electric baseboard heat (120/240V). If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Disconnect power before installation. Must be installed by a trained, experienced technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Connect wires and mount the wall plate using screws and anchors provided. A C-Wire (common wire) is needed for 24 VAC power. The thermostat will glow and display the screen for up to three minutes while it starts up.
  • Page 2: Setup: On-screen menus Using t, highlight Device Details and press OK. Using t, find the 4-digit password (date code) and record it above. Press and hold (Weather button) for 5 seconds to access the Main Menu. Using s, highlight Set Up and press OK. Using t, highlight Contractor and press OK. Enter the password by pressing or t to select the first digit and press OK. Highlight Set Up and press OK. Press s or t to highlight the setting and press OK. When all settings are configured, save changes. To exit setup early, press t to highlight EXIT and press OK.
  • Page 3: Setting setup options include minimum and maximum setpoints for temperature. From the Contractor Menu, highlight Set Up and press OK. Press s or t to highlight the setting and press OK. When all settings are configured, you will be prompted to save changes. Humidifier type options include None, Steam, and Bypass or fan powered. Temperature indication scale can be set to Fahrenheit or Celsius. Heating system types include conventional forced air heat, heat pump, and radiant heat. Dehumidification equipment options range from none to various types of air conditioning and dehumidifiers. Backup heat types include electric forced air and gas/oil forced air. Ventilation settings allow for control of fan operation and temperature lockouts.
  • Page 4: Round Smart Thermostat Basic Operations Turn to set desired temperature Turn on/off Cooling Heating Home/Away View 6 and 12 hour forecasts Set to Home/Away Regulatory information FCC regulations
  • Page 5: Thermostat intelligent Round™ Guide d’installation professionnelle Compatible avec les systèmes de 24 volts, comme les systèmes à air pulsé, les systèmes hydroniques, les thermopompes, les systèmes à l’huile, au gaz et électriques. Non compatible avec les chauffages de plinthes électriques (120/240 V). Si ce produit remplace un régulateur contenant du mercure dans un tube scellé, ne mettez pas l’ancien régulateur à la poubelle. Coupez l’alimentation électrique avant de commencer l’installation. L’installation doit être faite par un technicien d’expérience ayant reçu la formation pertinente. Lire attentivement ces instructions. Branchez les fils et fixez la plaque murale à l’aide des vis et ancrages fournis. Un fil C (fil neutre) est requis pour l’alimentation 24 V c.a. Lors de son démarrage, l’écran d’affichage du thermostat s’illumine jusqu’à trois minutes.
  • Page 6: Configuration : Menus affichés En utilisant t, sélectionnez Device Details (Informations sur l’appareil) et appuyez sur OK. Trouvez le mot de passe à 4 chiffres (code de date) et notez-le. Appuyez sur le bouton Météo pendant 5 secondes pour accéder au Menu principal. Sélectionnez Set Up (Configuration) et appuyez sur OK. Entrez le mot de passe en sélectionnant chaque chiffre puis appuyez sur OK. Sélectionnez Set Up (Configuration) et appuyez sur OK. Appuyez sur s ou t pour sélectionner le réglage puis appuyez sur OK. Une fois tous les paramètres configurés, sauvegardez les modifications. Pour sauvegarder et confirmer, sélectionnez Yes (Oui) et appuyez sur OK. Pour quitter la configuration à n’importe quel moment, appuyez sur t pour sélectionner EXIT (Quitter) puis appuyez sur OK.
  • Page 7: Point de consigne min. Ce paramètre s’applique aux points de consigne de chauffage et de climatisation. Point de consigne max. Type d’humidificateur. Échelle d’indication de température. Humidification - Protection des fenêtres. Type de système de chauffage. Régulation de l’humidification. Type d’équipement de chauffage. Équipement de déshumidification.
  • Page 8: Thermostat intelligent Round Fonctionnement de base Tourner pour régler la température désirée. Mise en marche/arrêt Refroidissement Chauffage À la maison/Afficher les prévisions sur 6 et 12 heures Réglez sur À la maison/Absent Informations réglementaires Cet appareil est conforme à la partie 15 du règlement de la FCC.
  • Page 9: Termostato inteligente Round™ TH8732WFH5004 Guía de instalación profesional Compatible con sistemas de 24 voltios, como de aire forzado, hidrónico, con bomba de calor. No trabaja con calefacción eléctrica de zócalo (120/240 V). Si este producto está reemplazando a un control que contiene mercurio en un tubo sellado, no coloque en la basura el control anterior. Desconecte la electricidad antes de comenzar la instalación. Debe ser instalado por un técnico capacitado y experimentado. Lea detenidamente estas instrucciones. Conecte los cables e instale la placa de pared. Se requiere un cable C (común) para una alimentación de 24 V CA. Durante su inicio, el termostato brillará y mostrará la pantalla hasta tres minutos.
  • Page 10: Setup (configurar): Menús en pantalla Utilizando t, marque Device Details (detalles del dispositivo) y presione OK (aceptar). Encuentre la contraseña de 4 dígitos (código de fecha) y regístrela. Presione y sostenga (botón del clima) durante 5 segundos para acceder al Menú principal. Utilizando s, marque Set up (configurar) y presione OK (aceptar). Ingrese la contraseña presionando o t para seleccionar el primer dígito y presione OK (aceptar). Presione s o t para marcar la configuración y presione OK (aceptar). Cuando todas las configuraciones se hayan efectuado, guarde los cambios. Para guardar y confirmar, marque Yes (Sí) y presione OK (aceptar). Para salir sin guardar, presione t para marcar No y presione OK (aceptar). Para salir de la configuración con anticipación, presione t para marcar EXIT (salir) y presione OK (aceptar).
  • Page 11: Descripción de la configuración del sistema. Opciones de configuración incluyen reactivación inteligente adaptable. La configuración se aplica a ambos puntos de referencia, calefacción y refrigeración. Para guardar cambios, marque Yes y presione OK. Tipos de sistema de calefacción incluyen calefacción de aire forzado convencional, bomba de calor y calefacción radiante. Control de humidificación puede ser activado solo cuando la calefacción o el ventilador están encendidos. Configuración del equipo de deshumidificación y control del ventilador son esenciales. Bloqueo de ventilación por temperatura baja y alta se puede ajustar. Temporizador de prioridad de la calefacción de reserva permite establecer intervalos de tiempo. Puntos de referencia en modalidad fuera de casa y dentro de casa son configurables.
  • Page 12: Termostato inteligente Round Funcionamiento básico Gire para configurar la temperatura deseada. Encienda/Apague Refrigeración Calefacción Vea la predicción del tiempo para 6 y 12 horas Configure para En casa/Fuera de casa Este dispositivo cumple con la Parte 15 de las normas de la Comisión Federal de Comunicaciones (FCC). Cualquier modificación realizada sin la aprobación expresa de la parte responsable del cumplimiento de las normas podría anular el derecho del usuario a utilizar el equipo.