Wiring conventional and heat pump systems  
E Aux Y  
G
O
L
R
B
C
W
Y
G
O
Rc  
R
B
C
2H/1C Heat Pump System TH3210D  
1H/1C Heat Pump System TH3110D [7]  
C
B
24 Vac common [3]  
Changeover valve energized in  
heating [5]  
C
B
24 Vac common [3]  
Changeover valve energized in  
heating [5]  
R
L
O
Power [1]  
R
[R+Rc joined by jumper]  
Sends output when set to Em. Heat [8]  
Changeover valve energized in  
cooling [5]  
Fan relay  
Compressor contactor  
Rc Power [1]  
O
Changeover valve energized in  
cooling [5]  
Fan relay  
Compressor contactor [6]  
[W+Y joined by jumper]  
G
Y
G
Y
W
Aux Auxiliary heat relay [9]  
Emergency heat relay [9]  
E
W
Rc  
R
C
O
B
W
Y
G
O
Rc  
R
B
C
Heat Only System TH3110D  
1H/1C System TH3110D (1 transformer)  
C
R
24 Vac common [3]  
[R+Rc joined by jumper]  
C
R
24 Vac common [3]  
[R+Rc joined by jumper]  
Rc Power [1]  
Rc Power [1]  
W
Heat relay  
G
Y
W
Fan relay  
Compressor contactor  
Heat relay  
W
G
O
Rc  
R
B
C
Heat Only System with Fan TH3110D  
W
Y
G
O
Rc  
R
B
C
C
R
24 Vac common [3]  
[R+Rc joined by jumper]  
1H/1C System TH3110D (2 transformers)  
Rc Power [1]  
G
W
C
R
24 Vac common [3, 4]  
Power (heating transformer) [1, 2]  
Fan relay  
Heat relay  
Rc Power (cooling transformer) [1, 2]  
G
Y
W
Fan relay  
Compressor contactor  
Heat relay  
Y
G
O
Rc  
R
B
C
Cool Only System TH3110D  
C
R
24 Vac common [3]  
[R+Rc joined by jumper]  
Rc Power [1]  
G
Y
Fan relay  
Compressor contactor  
NOTES  
Wire specifications:  
Use 18- to 22-gauge thermostat wire.  
Shielded cable is not required.  
[6] Use a small piece of wire (not supplied) to  
connect W and Y terminals.  
[1] Power supply. Provide disconnect means  
and overload protection as required.  
[2] Remove jumper for 2-transformer sys-  
tems.  
[3] Optional 24 Vac common connection.  
[4] Common connection must come from  
cooling transformer.  
[7] Set fan operation switch to Heat Pump  
(see page 5) and configure system type  
for heat pump (see page 6).  
[8] L terminal sends a continuous output  
when thermostat is set to Em. Heat.  
Connect to Honeywell Home zoning pan-  
els to switch the panel to Emergency Heat.  
[9] Install field jumper between Aux and E if  
there is no emergency heat relay.  
[5] Use either O or B terminals for change-  
over valve.  
3
GeneralDetails
NameHoneywell TH3110D1008 Non-Programmable Thermostat Instruction Manual
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.98 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell TH3110D1008 Non-Programmable Thermostat Instruction Manual