Honeywell T6 Pro Programmable Thermostat Instruction Manual
Advanced setup options (ISU)
# ISU
ISU Name
ISU Options (factory default in bold)
221
Heat Stages / Backup Heat Stages
Heat Stages: 1, 2
Backup Heat Stages: 0, 1
230
253
255
Fan Control in Heat
1 = Equipment Controls Fan
2 = Thermostat Controls Fan
Aux/E terminal control (TH6320
only)
0 = Drive both Aux & E together
1 = Aux and E independent
Backup Heat Source
(Heat Pump Only)
1 = Electric Forced Air
2 = Gas/Oil Forced Air (or Fossil Forced Air)
256
260
270
Emergency Heat Source (TH6320
only)
1 = Electric Forced Air
2 = Gas/Oil Forced Air (or Fossil Forced Air)
External Fossil Fuel Kit
(TH6320 / TH6220 only)
0 = Thermostat Controls Backup Heat
1 = External Fossil Fuel Kit Controls Backup Heat
Backup Heat Fan
1 = Equipment Controls Fan
2 = Thermostat Controls Fan
Note: Setting only active with TH6320 in Heat Pump mode.
271
Emergency Heat Fan
1 = Equipment Controls Fan
2 = Thermostat Controls Fan
Note: Setting only active with TH6320 in Heat Pump mode.
300
303
System Changeover
0 = Manual
1 = Automatic
Auto Changeover Differential
0 °F to 5 °F
0.0 °C to 2.5 °C
Note: Differential is NOT deadband. Differential means how far past the setpoint
before switching to the mode selected. Deadband setup is not an option.
Honeywell uses an advanced algorithm that fixes deadband at 0 °F. This is more
advanced than previous thermostats.
340
350
Backup Heat Droop
0 = Comfort
2 = 2 °F
9 = 9 °F
10 = 10 °F
11 = 11 °F
12 = 12 °F
13 = 13 °F
14 = 14 °F
15 = 15 °F
3 = 3 °F
4 = 4 °F
5 = 5 °F
6 = 6 °F
7 = 7 °F
8 = 8 °F
Upstage Timer for Backup Heat
0 = Off
1 = 30 minutes
2 = 45 minutes
3 = 60 minutes
4 = 75 minutes
5 = 90 minutes
6 = 2 hours
7 = 3 hours
8 = 4 hours
10 = 5 hours
355
Compressor Lockout / Balance Point
Outdoor Lockout Backup Heat
-- = Off
5 °F to 60 °F (in 5 °F increments)
-15.0 °C to 15.5 °C (in 2.5 °C or 3.0 °C increments)
Note: Use a wired sensor to set compressor lockout / balance point on TH6320
/ TH6220.
356
-- = Off
5 °F to 65 °F (in 5 °F increments)
-15.0 °C to 18.5 °C (in 2.5 °C or 3.0 °C increments)
365
366
370
371
Compressor Cycle Rate (Stage 1)
Compressor Cycle Rate (Stage 1)
Heating Cycle Rate (Stage 1)
Heating Cycle Rate (Stage 2)
1 - 6
1 - 6
1 - 12
1 - 12
8
| General | Details |
|---|---|
| Name | Honeywell T6 Pro Programmable Thermostat Instruction Manual |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.01 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell Lyric T5 Wi-Fi Thermostat Installation Guide