HBX THM-0500 Touch Screen Programmable Thermostat Instruction Manual
Fancoil Setup
Fan on demand
Fancoil Setup: Fan On Demand
This option will turn the fan on with any fancoil demand.
Zone on demand
Temp Average
Fan Mode
N
o
n
e
Fancoil Setup
Fan on demand
Fancoil Setup: Zone On Demand
This option will turn the zone pump on with any fancoil
demand.
Zone on demand
Temp Average
Fan Mode
None
Fancoil Setup
Fan on demand
Fancoil Setup: Temperature Averaging
This option will average the temperature between
thermostats (User Selectable), when that average falls
below or above the setpoint, depending on if it’s in
heating or cooling, then the thermostat will make a call
for heating or cooling on the fancoil.
Zone on demand
Temp Average
Fan Mode
1 - 4
Fancoil Setup
Fan on demand
Fancoil Setup: Fan Mode
OFF: Fan is off
ON: Enables the fan to run constantly, regardless of
whether the thermostat is calling for heating or cooling
INT: This setting will set the ON/OFF time for the
intermittent fan
Zone on demand
Temp Average
Fan Mode
None
Ex: The fan will come on for 15 min every 2H. Set (Int Fan
On: 15 min) & (Int Fan Off: 2H)
Fancoil Setup
Fan on demand
Fancoil Mode INT: Intermittent Fan On
Sets the amount of time the fan will operate. Only
applicable when Fan Mode is set to INT.
Zone on demand
Temp Average
Fan Mode
None
Int
Int Fan ON
2 mins
2 hrs
Int Fan OFF
13