GENERAL SENNA 300 Digital Room Thermostat User Manual
ScreenIndicators
MODESETTING
Low Battery Warning: When the “
” icon appears on the screen, it means
ENGLISH
“low battery warning”. It is recommended to replace the batteries when this
warning appears.
MODES
1
8
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty.
2
DIGITAL ROOM THERMOSTAT
9
10
WEEKLY
PROGRAM
MODE
PRESET MODES
MANUAL MODE
3
4
generallife.com.tr
Please throwyour dead batteries into thewaste bin forbatteries.
Economy
Mode
Comfort
Mode
ROOMTHERMOSTATWIRINGDIAGRAM
5
SENNA 300 USER MANUAL
Your Room Thermostat has 4 different modes. 3 of them (Comfort and
Economy Mode) are preset modes. Other modes are manual mode and
weeklyprogram mode.
HEATING/COOLING UNIT
6
7
GENERALSPECIFICATIONS
1
2
3
4
5
6
7
8
Hour Indicator
Day Indicator
Room Temperature
Set Temperature
Economy Mode
Comfort Mode
Weekly Program Mode
Battery Indicator
Heating Indicator
In preset modes, temperature values are based on user's choices which
have been set in the beginning. Manual mode allows the Room Thermostat
to operate within the temperature which is required and set directly by user.
Weekly Program mode continues to work according to the weekly schedule
determined bytheuser.
SENNA 300 is a wired room thermostat. The user can adjust the room
temperature with the required temperature and get more comfortable and
economic heating/cooling.
Dailyand WeeklyProgramming
Different Mode Options (Comfort, Economy)
In order to change the temperaturevaluesof presetmodes:
NO COM
Heating Calibration
ON/OFFControl
Wired Connection
Press and hold the “Mode” button for
Thermostatis on.
3
seconds while your Room
Heating/Cooling Option
TPIAlgorithm
PreciseTemperature Measurement
9
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
Comfort Mode temperature value will appear. You may adjust the
temperaturevalueof Comfort Mode bypressingthe“+” and “-” buttons.
When setting is done, you may adjust the temperature value of Economy
Mode withthe“+” and “-” buttons bypressing the “Mode”button again.
You mayexitthesetting screen bypressing the“Mode”button 3 seconds.
In order to change the manual mode temperature, press the “+” or “-”
button while in the main screen. The Room Thermostat will switch to
ManualMode once pressedthe“+” or “-” button.
Warning!
Operations within the heating / cooling unit or the electrical installation
must be carriedout byprofessionally qualified persons.
SENNA 300AND EQUIPMENTS
10
SENNA 300 Room Thermostat
Alkaline
Battery
Dowels and Screws
ROOMTHERMOSTATTEMPERATURECALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like
to get the same temperature values with other thermometers in your living
space.
ROOMTHERMOSTATPLACEMENT
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room or side
of window should be avoided. Also anywhere close to heating/cooling units
such as radiator, stove and spots which get direct sun lights would not be
suitable. Room Thermostat needs to be located above the floor 150 cm
height. Fewtrialsmaybe made to find themost convenientspot.
You maypressthe“Mode”button to switchto theother modes.
While your device is turned off, press and hold the “On/Off“ button for 3
seconds.
WEEKLY PROGRAM
TECHNICALDATA
Dimensions
Operating Current
Relay NO Switching Current
You may set the operating schedule of your Room Thermostat with weekly
program mode. 7 different temperature values can be set for each day in
weekly programming. These values can be set in temperature adjustment
screens '' P0-P6''.
Press the "On/Off" button until the “
” menu appears. In order to see
85mm / 125mm / 19mm
3V DC (2 x AAA alkaline battery)
2A (30VDC – Resistive load)
0.5A (125VAC – Resistive load)
the desired temperature, set the temperature difference by pressing the
“Temperature Adjustment Buttons”. This value can be arranged between
“-8°C" and “+8° C".
Temperature Measurement Accuracy 0.1oC
Operating Temperature Range
Battery Life
Operating Temperature
Storage Temperature
In order to set the weekly schedule, press and hold the “Weekly Program“
button for 3 seconds while your Room Thermostat is on. The “Hour,
Minute and Day” setting will appear. Press the “Heating & Cooling Option”
button untilthe“WeeklyProgram”menu (P0)appears.
In order to save the settings and exit, press the "On/Off" button until the
deviceturns off.
(5oC) – (30oC)
1 Years (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Note:Recommended temperature calibration is “0.0°C”.
Days of the week will be blinking on the screen. You can initiate the weekly
program setting if you wish to set the same schedule for every day of the
week.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This
operation resets the mode temperature values, calibration setting and
heating/cooling modes to factory setting. In order to reset your Room
Thermostatto factory setting:
ROOMTHERMOSTAT
Buttons Functions
Press the “+” button once if you wish to set the same schedule for the
weekdays. Firstfivedaysof weekwill be blinking on thescreen.
Press the “+” button once more if you wish to set the same schedule only
for theweekend. Lasttwodaysof the weekwill be blinking on thescreen.
Press the “+“ button one more time if you wish to set the same schedule
for every day of the week. 1st day of the week will be blinking on the
screen. You can switch between the days by pressing the “+” button.
Press the“-” button in order to switchto the previousday.
While your device is turned off, press and hold the “On/Off” button for 3
seconds.
1
Pressthe“On/Off” button untilthe“
While in the “ ” menu, select the “
buttons and pressthe“On/Off” button.
Your devicewill be turned off and resetto factory settings.
” menu appears.
” option by using the “+” or “-”
2
3
4
Press the“WeeklyProgram“button once to setaschedule.
“P0” will be blinking on the screen. Set the temperature value of “P0” by
pressing the “Weekly Program“button once more. The hour setting of “P0”
cannot be changed since it's factory setting.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room Thermostat
and make surethatthe energy is cut off.
DAY AND HOURSETTINGS
While your Room Thermostat is on, keep pressing the “Weekly Program”
button for 3 seconds.
5
6
Press the “Weekly Program” button again. Day indicator will be blinking. If
you will not change the day, press the “Weekly Program” button again and
switchto the“P1” settingbypressing the“+” button.
At the first screen that appears, hour part will be blinking. You may set the
timewiththe“+” and“-” buttons.
1
2
3
4
5
6
ON/OFF Button
Weekly Program Button
Mode Button
Heating & Cooling Option
Temperature Adjustment (Increasing)
Temperature Adjustment (Decreasing)
After setting the time, the “Heating & Cooling Option” button needs to be
pressed once. For minute setting, minute part will be blinking. You mayset
the minute withthe“+” and“-” buttons.
First, hour setting will appear on the screen. Once you complete the hour
setting, adjust the minute setting by pressing the “Weekly Program”
button. After the minute setting, press the “Weekly Program” button to set
thetemperaturevalue.
After setting the minute, the “Heating & Cooling Option” button needs to
be pressed once to setthe dayof theweek.
Follow thesamesteps for other schedule settings.
Mondayhas setasthe firstdayof the weekand indicated withnumber“1".
Numbers indicate the following days respectively 2-Tuesday,
3-Wednesday, 4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday
When setting is done, you may exit by pressing the “Weekly Program”
button for 3 seconds.
Once all changes made, press and hold the “Weekly Program” button for 3
seconds to save.
Note: In order to check the weekly schedule which has been set without
making any changes, press the “Weekly Program” button once while your
Room Thermostat is on. Press the “+” and “-” buttons to see the days, press
the“Mode”button to seethe settingsbetween“P0-P6”.
As shown in the picture above, press the screwdriverforward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace
both batteries at the same time. Then align the front part of your Room
Thermostatto thebackand squeezeittowards theback.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL SENNA 300 Digital Room Thermostat User Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.07 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL MITRA 220 RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Low battery warning: When the icon appears on the screen, it indicates a low battery warning. It is recommended to replace the batteries when this warning appears. Warning: When the product is not used for a long period (more than 15 days), remove the batteries to avoid malfunctions that may occur. Your Room Thermostat has 4 different modes: 3 preset modes (Comfort and Economy) and manual mode. In preset modes, temperature values are based on user's choices set initially. Manual mode allows direct user temperature setting. Weekly Program mode continues to work according to the weekly schedule determined by the user. SENNA 300 is a wired room thermostat that allows users to adjust room temperature for comfortable and economic heating/cooling. You may set the operating schedule of your Room Thermostat with weekly program mode, allowing 7 different temperature values for each day. You can reset your Room Thermostat to its default factory settings, which resets mode temperature values and calibration settings. Room Thermostat needs to be placed in frequently used rooms, avoiding areas with direct sunlight or near heating/cooling units. Before starting, power off the device connected to the Room Thermostat and ensure that the energy is cut off.
- Page 2: What to know about TPI room thermostat Warranty conditions The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years. Your room thermostat works with the TPI algorithm, predicting temperature changes to maintain the set temperature with minimal deviation. If the placement of the TPI room thermostats is changed or they are de-energized, the learning process will restart and should be considered as 7 days. Devices and apparatus are delivered in working condition, with on-site commissioning subject to a service fee. The repair of devices covered by the warranty is carried out in the company factory, with transportation costs borne by the customer. TPI technology ensures optimal energy efficiency by measuring and applying the best timings for maintaining the desired temperature. In non-TPI thermostats, the heating/cooling unit operates continuously, leading to greater temperature fluctuations compared to TPI thermostats. Malfunctions caused by customer misuse are not covered by the warranty, and all expenses would belong to the customer. The warranty document must be kept by the customer during the warranty period, and a second document will not be issued if lost.














