Home > GENERAL > GENERAL FH101S Underfloor Heating Thermostat User Manual

GENERAL FH101S Underfloor Heating Thermostat User Manual

ROOM THERMOSTAT PLACEMENT  
WIRING DIAGRAM FOR ACTUATOR  
ENGLISH  
Place your Room Thermostat in a room you use frequently in your  
living space. For example; like the hall or living room of your home.  
Avoid installing the Room Thermostat in places where there is a lot of  
air circulation, such as at the doorway or by the window. Also, do not  
place it close to heating units (heater core, fireplace, etc.) and in direct  
sunlight. We recommend that the room thermostat is placed at a  
height of 150cmfrom theoor.  
N
L
L1  
N1  
UNDERFLOOR HEATING THERMOSTAT  
generallife.com.tr  
FH101S USER MANUAL  
min. 20 cm  
GENERAL SPECIFICATIONS  
UNDERFLOOR HEATING THERMOSTAT  
FH101S is a floor heating room thermostat. User provides more  
comfortable and affordable heating by setting needed room  
temperature.  
SensitiveTemperatureMeasurement  
Wired Connection  
ACTUATOR  
ON/ OFFControl  
ROOM THERMOSTAT WORKING PRINCIPLE  
FH101S  
USER MANUAL  
As soon as you energize your Room Thermostat, it will start working.  
Your Room Thermostat measures the temperature of the  
environment it is in every 5 seconds. If the ambient temperature rises  
0.5 degrees above the temperature you set, your Room Thermostat  
turns off the heating unit, and if it falls below 0.5 degrees, it turns on  
theheating unit.  
FH101S AND EQUIPMENTS  
230V AC  
FH101S Room Thermostat  
Dowels and  
Screws  
WIRING DIAGRAM FOR WIRING CENTER  
If the floor sensor measures temperature above 28°C, it turns off the  
heating unit. The floor sensor operating sensitivityis ±1°C.*  
Thus, it is ensured that the ambient temperature remains within a  
certain range.  
N
L
L1  
N1  
*Externaloor sensor is only activewhen itis connected.  
TECHNICAL DATA  
Note: If a floor sensor is installed with Room Thermostat, only  
GENERAL Life floor sensor should be installed. Otherwise, the  
product willbe out of warranty.  
Dimensions ( H / L / W )  
Operating Current  
Relay NO Switching Current  
85.7mm / 85.7mm / 33.5mm  
230V AC  
7A (240VAC – Resistive load)  
10A (120VAC – Resistive load)  
0.1oC  
ROOM THERMOSTAT WIRING DIAGRAM  
Temperature Measurement  
Accuracy  
1
2
3
4
Operating Sensitivity  
Operating Temperature Range  
Operating Temperature  
Storage Temperature  
0.5oC  
(5oC) – (30oC)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
WIRING  
CENTER  
230V AC  
ROOM THERMOSTAT  
WARNING!  
Indicator LED  
Set Button  
Operations related to the control panel, heating unit or electrical  
installation must be carried out by persons with professional  
qualifications.  
5
N
L
NTC  
L1  
N1  
WARNING!  
6
RoomThermostatIndicator LED Descriptions  
The assembly of product  
LED light is on  
LED light is off  
Heating unit is working  
should be done according to  
the image above.  
Heating unit is not working  
For electrical connection,  
please see diagram 5.  
Should not be used in case  
the usage of a wiring center.  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL FH101S Underfloor Heating Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size1.95 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL FH101S Underfloor Heating Thermostat User Manual
Get the free PDF manual for the GENERAL FH101S Underfloor Heating Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL FH101S Underfloor Heating Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat placement is crucial for effective heating. Place your room thermostat in a frequently used room, avoiding areas with high air circulation or direct sunlight. The recommended height for installation is 150 cm from the floor. The FH101S is a floor heating room thermostat that allows users to set their desired room temperature. It features sensitive temperature measurement and wired connection for reliable operation. The thermostat measures ambient temperature every 5 seconds, turning the heating unit on or off based on the set temperature. If the floor sensor detects a temperature above 28°C, it will turn off the heating unit to maintain a safe range. Only the General Life floor sensor should be used with the room thermostat to ensure warranty coverage. Operations related to the control panel and electrical installation should be performed by qualified professionals. The indicator LED provides visual feedback on the heating unit's operational status.
  • Page 2: WARRANTY CERTIFICATE The warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years. Devices and apparatus are delivered to the customer in working condition. The repair of the devices and apparatus covered by the warranty is carried out in our company factory. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault. The warranty document must be kept by the customer during the warranty period. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty. Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty. The customer can make complaints and appeals to consumer courts or consumer arbitration committees. All of the devices and apparatuses, including all their parts, are under the warranty of our company.