GENERAL FH101S Underfloor Heating Thermostat User Manual
ROOM THERMOSTAT PLACEMENT
WIRING DIAGRAM FOR ACTUATOR
ENGLISH
Place your Room Thermostat in a room you use frequently in your
living space. For example; like the hall or living room of your home.
Avoid installing the Room Thermostat in places where there is a lot of
air circulation, such as at the doorway or by the window. Also, do not
place it close to heating units (heater core, fireplace, etc.) and in direct
sunlight. We recommend that the room thermostat is placed at a
height of 150cmfrom thefloor.
N
L
L1
N1
UNDERFLOOR HEATING THERMOSTAT
generallife.com.tr
FH101S USER MANUAL
min. 20 cm
GENERAL SPECIFICATIONS
UNDERFLOOR HEATING THERMOSTAT
FH101S is a floor heating room thermostat. User provides more
comfortable and affordable heating by setting needed room
temperature.
SensitiveTemperatureMeasurement
Wired Connection
ACTUATOR
ON/ OFFControl
ROOM THERMOSTAT WORKING PRINCIPLE
FH101S
USER MANUAL
As soon as you energize your Room Thermostat, it will start working.
Your Room Thermostat measures the temperature of the
environment it is in every 5 seconds. If the ambient temperature rises
0.5 degrees above the temperature you set, your Room Thermostat
turns off the heating unit, and if it falls below 0.5 degrees, it turns on
theheating unit.
FH101S AND EQUIPMENTS
230V AC
FH101S Room Thermostat
Dowels and
Screws
WIRING DIAGRAM FOR WIRING CENTER
If the floor sensor measures temperature above 28°C, it turns off the
heating unit. The floor sensor operating sensitivityis ±1°C.*
Thus, it is ensured that the ambient temperature remains within a
certain range.
N
L
L1
N1
*Externalfloor sensor is only activewhen itis connected.
TECHNICAL DATA
Note: If a floor sensor is installed with Room Thermostat, only
GENERAL Life floor sensor should be installed. Otherwise, the
product willbe out of warranty.
Dimensions ( H / L / W )
Operating Current
Relay NO Switching Current
85.7mm / 85.7mm / 33.5mm
230V AC
7A (240VAC – Resistive load)
10A (120VAC – Resistive load)
0.1oC
ROOM THERMOSTAT WIRING DIAGRAM
Temperature Measurement
Accuracy
1
2
3
4
Operating Sensitivity
Operating Temperature Range
Operating Temperature
Storage Temperature
0.5oC
(5oC) – (30oC)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
WIRING
CENTER
230V AC
ROOM THERMOSTAT
WARNING!
Indicator LED
Set Button
Operations related to the control panel, heating unit or electrical
installation must be carried out by persons with professional
qualifications.
5
N
L
NTC
L1
N1
WARNING!
6
RoomThermostatIndicator LED Descriptions
The assembly of product
LED light is on
LED light is off
Heating unit is working
should be done according to
the image above.
Heating unit is not working
For electrical connection,
please see diagram 5.
Should not be used in case
the usage of a wiring center.
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL FH101S Underfloor Heating Thermostat User Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.95 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL FH101S Underfloor Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat placement is crucial for effective heating. Place your room thermostat in a frequently used room, avoiding areas with high air circulation or direct sunlight. The recommended height for installation is 150 cm from the floor. The FH101S is a floor heating room thermostat that allows users to set their desired room temperature. It features sensitive temperature measurement and wired connection for reliable operation. The thermostat measures ambient temperature every 5 seconds, turning the heating unit on or off based on the set temperature. If the floor sensor detects a temperature above 28°C, it will turn off the heating unit to maintain a safe range. Only the General Life floor sensor should be used with the room thermostat to ensure warranty coverage. Operations related to the control panel and electrical installation should be performed by qualified professionals. The indicator LED provides visual feedback on the heating unit's operational status.
- Page 2: WARRANTY CERTIFICATE The warranty period starts from the invoice date and is warranted against manufacturing defects for 2 years. Devices and apparatus are delivered to the customer in working condition. The repair of the devices and apparatus covered by the warranty is carried out in our company factory. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault. The warranty document must be kept by the customer during the warranty period. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty. Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty. The customer can make complaints and appeals to consumer courts or consumer arbitration committees. All of the devices and apparatuses, including all their parts, are under the warranty of our company.