SPECIFICATIONS
Electrical Rating:
Input-Hardwire
Load
24 VAC (18-30 VAC)
-1 amp maximum per output
-4 amp maximum total load
Setpoint Range
60° to 85° F (16° to 29° C)
Operating Ambient
40º F to 99º F (4º C to 37º C)
Occupancy Sensor Range
5 meters, 109.6 degrees x 109.6 degrees
Field of View
O1/O2 Dry Contact Ratings .5A @ 32VAC or .5A @ 30VDC
Humidity Range/Accuracy
0 to 95% operating humidity range, +/- 5%
accuracy
Shipping Temperature
Range
-30°F to + 150°F (-34° to +65°C)
Thermostat Dimensions
3.9” H x 5.4” W x 1.03”
MERCURY NOTICE: This product does not contain mercury.
However, this product may replace a product that contains
mercury. Mercury and products containing mercury must not be
discarded in household trash. Refer to thermostat-recycle.org
for information on disposing of products containing mercury.
Thermostat Applications
Maximum Stages Heat/ Cool
Single Stage Cooling, One or Two
Stage Heating
NOTE: Two stage heating = 1st
stage heat pump and 2nd stage
resistance heat
Two Stage Cooling, Three Stage
Heating
3/2
NOTE: Three stage heating = 2
stage heat pump and 3rd stage
resistance heat
2-Way Communication with select
GE Appliance products
2
31-5000842 Rev. 0
| General | Details |
|---|---|
| Name | GE APPLIANCES RAK190V 2 Way Energy Management Thermostat Instruction Manual |
| Make | GE Appliances |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.37 MB |

GE APPLIANCES RAK160W2 Wireless Thermostat User Manual

GE APPLIANCES RAK150VF2 Wall Thermostat Instruction Manual

GE APPLIANCES RAK190V Energy Management Thermostat Owner’s Manual

GE APPLIANCES RAK150VF2 Digital Wall Thermostat Instruction Manual

GE APPLIANCES THERMOSTAT Owner’s Manual