Installation manual  
Installation manual  
Installation manual  
Installation manual  
Under power on state, press  
seconds;  
and  
at the same time  
3
Week Programmable Thermostat System Default Value in the Period of  
Constant, Heating and Cooling  
Insert Card Thermostat Menu Function and Explanation  
9. System Function Explanation:  
Valve Control  
Hot Water Valve On  
● Enter setting state, programmable menu F(blinking display) is  
under selected;  
● Short press ▲ key(or short press ▼ key) switch menu options  
F0-F6;  
Menu Funcꢀon  
Set range  
Week  
Explanaꢀon  
Cold Water Valve On  
Cooling  
Temperature Set (°C)  
Starꢀng  
Time  
1
7
~
Aſter adjusꢀng the min. parameter, press  
key to confirm, the internal second  
count will be cleared at the same ꢀme,  
which can realize the precise ꢀme set.  
Period  
System Time  
Adjustment  
Monday - Friday  
Saturday, Sunday  
F0  
Hour  
0
23  
59  
~
~
Constant  
Heaꢀng  
20  
Cooling  
24  
Constant  
Heaꢀng  
20  
Cooling  
24  
Minute  
0
● Short press  
key enter the parameter settings state of  
P1: 6:00 8:00  
~
6:00  
8:00  
20  
22  
20  
24  
20  
22  
20  
24  
No card heaꢀng set  
temperature  
corresponding menu;  
● Press ▲ key(or press ▼ key)change parameter value;  
F1  
F2  
F3  
5°C 22°C (Default 18°C)  
~
P2: 8:00 16:00  
~
18  
26  
18  
26  
Under no card status system will adjust the  
set temperature into the corresponding  
24°C 35°C (Default 26°C) economic operaꢀon temperature, to  
P3: 16:00 22:00  
~
16:00  
22:00  
20  
24  
20  
24  
No card cooling set  
temperature  
● Short press  
confirm this setting, return to the previous menu  
~
P4: 22:00 next 6:00  
~
18  
26  
18  
26  
achieve no card energy-saving operaꢀon.  
or select the next parameter;  
No card thermostat set  
temperature  
Hot Water Valve Off  
Cold Water Valve Off  
Heating  
20°C 26°C (Default 22°C)  
~
● Short press  
key cancel this setting, and return to the previous  
T: Room Temperature  
S: Set Temperature  
Es: Converted Deviation (Default 3°C)  
menu.  
Timing Thermostat Menu Function and Explanation  
0
Fan out of control  
F4  
Fan under control set  
Power-on recovery set  
Functional Diagram of Heating, Cooling and Constant Mode  
Fan Control  
1 (Default Value)  
0 (Default Value)  
1
Fan under control  
Menu Funcꢀon  
Set range  
Week  
Explanaꢀon  
Week Programmable Thermostats Menu Function and Explanation  
Power-on recovery funcꢀon is forbidden  
Power-on recovery funcꢀon is available  
F5  
1
7
~
Aſter adjusꢀng the min. parameter, press  
key to confirm, the internal second  
count will be cleared at the same ꢀme,  
which can realize the precise ꢀme set.  
Menu Funcꢀon  
Range  
Week  
Hour  
Explanaꢀon  
System Time  
Adjustment  
Keep high/mid/low fan speed  
Keep high/mid/low fan speed  
F0  
F1  
Hour  
0
23  
59  
~
~
Manual  
Manual  
Adjust room  
temperature  
The room temperature will be increased  
or reduced by 0.5°C  
Aſter adjusꢀng the Minute parameter,  
press  
internal second count will be leared at  
the same ꢀme, which can realize the  
precise ꢀme set.  
F6  
-5°C +5°C  
~
1
7
~
Minute  
0
key to confirm and the  
High Speed  
High Speed  
Mid Speed  
System Time  
Adjustment  
Auto  
Auto  
0
23  
59  
F0  
F1  
~
~
0
Fan out of control  
Mid Speed  
Fan under control set  
Power-on recovery set  
Minute  
0
Low Speed  
Low Speed  
1 (Default)  
Fan under control  
Insert Card Function Explanation  
Starꢀng Hour  
0
0
23  
59  
~
~
0 (Default Value)  
Power-on recovery funcꢀon is forbidden  
Power-on recovery funcꢀon is available  
If the clients select the insert card type thermostat, please properly  
connected to the card in accordance with wiring diagram in the  
product bed. No card mark is displayed on the LCD panel when  
no card, the system into the economic operation mode, the set  
temperature pre-programmed by the staff.  
Set the data of 4 ꢀme  
periods (P1 P4) from  
F2  
F3  
Starꢀng Minute  
~
the 1st day to 5th day  
1
The starꢀng ꢀmes of  
4
ꢀme periods  
Seꢁng  
Temperature  
5
35 (P1~P4) are without sequence, one ꢀme  
period will be thrown away if you set the  
same starꢀng ꢀme, that is, the next ꢀme  
period will screen the previous one out.  
~
Adjust room  
temperature  
The room temperature will be increased  
or reduced by 0.55°C  
T: Room Temperature  
S: Set Temperature  
Es: Converted Deviation (Default 3°C)  
-5°C +5°C  
~
Set the ꢀme periods of  
the 6th day  
F2  
F3  
The same as F1  
The same as F1  
Fan Speed Switch Diagram of Heating/Cooling Mode  
Sleep Mode  
Set the ꢀme periods of  
the 7th day  
A
card into the normal operating mode, the user can set the  
temperature and wind speed. Economic model without card, the  
user can switch, but can not change the set temperature, can not set  
system parameters and recovery system.  
0
Fan out of control  
F4  
Fan under Control or not  
1 (Default)  
0 (Default)  
1
Fan under Control  
Power-on recovery funcꢀon is forbidden  
Power-on recovery funcꢀon is available.  
Power-on Recover  
Funcꢀon  
F5  
Refrigeration status of  
Heating status of sleep  
mode temperature curve  
sleep mode temperature curve  
Room Temperature  
Correcꢀon  
Increase or decrease the room  
temperature by 0.5°C  
F6  
-5°C +5°C  
~
- 7 -  
- 8 -  
- 9 -  
- 10 -  
Installation manual  
Installation manual  
Installation manual  
Installation manual  
11.3 The thermostat should be installed correctly by the professionals  
according to the manual;  
10. The solution of abnormal problems:  
Note  
Note  
Please check again if the N-wire and L-wire are connected correctly;  
if the cooling and heating running mode set is in accordance with the  
requirements.  
11.4 Please don’t install the thermostat near the high temperature heat  
source or in bad environment;  
11.5 Please make sure the power is the same as the voltage marked on  
the controller before installation;  
Funcꢀon  
Range  
Explanaꢀon  
Long press  
11.6 The functions and specification of thermostat will be updated  
gradually without further notice;  
Display”off” when the  
power is on.  
Did not switch on the ON/OFF key  
Key  
Terminal  
L-wire,Terminal  
N-wire  
1
is not connected with  
is not connected with  
Make sure the power of terminal 1  
and 7 is correct.  
7
There is no display  
when power on  
The connecꢀon of LCD Main Board and  
drive power are loose.  
Check the wires.  
The actual fan speed  
does not comply with the The connecꢀng sequence of terminal 2, Check the external lines.  
display.  
3 and 4 is wrong  
The wires are not connected  
well or loose.  
Check the wires  
Normal display, but  
wrong control  
The wire connecꢀon is wrong  
Temperature has not been adjusted.  
NTC (Sensor)  
Check the external lines.  
Adjust the measured temperature  
again  
Room  
temperature  
(Measured temperature)  
deviaꢀon  
Check the sensor  
Improve the installaꢀon  
environment.  
The installaꢀon locaꢀon is unsuitable  
Display trouble code Err1 Internal sensor goes wrong.  
Exchange the internal sensor  
Warning:  
11. Notice  
11.1 Please read the manual carefully before using, if you have any  
questions, please contact with the professional engineer of our  
company;  
The symbol means the unit is being installed, it may cause electrical  
shock hazard during maintaining, so please make sure it is operated  
by the professional technical worker.  
11.2 This thermostat must have individual electrical power control  
equipment. If you will not use it for a long time(over one month),  
please cut off the electrical power;  
- 11 -  
- 12 -  
- 13 -  
- 14 -  
GeneralDetails
NameFerono FTH-30 Universal Thermostat Instruction Manual
MakeFerono
LanguageEnglish
FiletypePDF (Download)
File size0.99 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...

Ferono FTH-30 Universal Thermostat Instruction Manual