fastwarm 16AMP Touchscreen Thermostat Instruction Manual
1.
2.
Room Temperature calibration: Calibrate
the temperature detected by room sensor.
9.
Schedule: Select a weekly schedule for the
event.
7: each day from Mon to Sun can be set
individually.
5+1+1: Mon to Fri have the same events, Sat
and Sun can be set individually.
No.
1
Name
Default
0.0°C
0.0°C
ON
Ranges
Room Temperature Calibration
Floor Temperature Calibration
Anti-Frozen Function
Anti-Frozen Temperature
Floor Temperature Limit
Temperature Tolerance
Temperature Unit
Sensor Selection
Schedule
-5.0°C -- 5.0°C
-5.0°C -- 5.0°C
OF(OFF) ON
5.0°C -- 15.0°C
20.0°C -- 50.0°C
0.5°C/1°C/2°C/3°C
°C/ °F
Floor Temperature calibration: Calibrate
the temperature detected by floor sensor.
2
3&4. Anti-frozen function: If the Anti-frozen
function opened, it will keep the room and
floor at a lower temperature in order to
protect the pets and plants in your house.
Also, it can protect your pipe against
freezing when using the water heating
system.
3
10. Output delay: This option help you avoid
4
5.0°C
30.0°C
1°C
inadvertent operation on heating.
11. Adaptive function: After several days of
installation and use, Adaptive function
5
6
ensures that the required temp has already
been reached when the next event begins.
5.
Floor temperature limit: When choose both
sensors, you can set the maximum floor
temperature value, system will stop heating
if the floor temperature exceed this value.
7
°C
12. Open window: This function only works
when room sensor or both sensors is
selected.
8
Floor
5+1+1
0 Sec
OFF
Room/Floor/Both
5+1+1/7
9
The thermostat with this function will
shut off automatically for 15 min when the
window opens, as it can detect that the
room temp plummets.
6.
Adaptive function: After several days of
installation and use, Adaptive function
ensures that the required temperature has
already been reached when the next event
begins.
10
11
12
13
14
15
Output Delay
0S/30S/60S/90S
ON/OFF
Adaptive Function
Open Window
OFF
ON/OFF
13&14. Energy use: This option allows you to
enter the various data used to calculate
energy use.
7.
8:
Temp unit: °F and °C can be selected.
Power Set
0 W
0W -- 4500W
Sensor selection
Energy Use
15. Factory Reset: All parameters are restored
Room sensor: Run by room sensor.
Floor sensor: Run by floor sensor.
Both sensors: Run by room sensor with
floor temp limit.
to default values.
Factory Reset
NO
NO/YES
14
15
| General | Details |
|---|---|
| Name | fastwarm 16AMP Touchscreen Thermostat Instruction Manual |
| Make | fastwarm |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

fastwarm HM-01-16A Digital Programmable Thermostat Instruction Manual