C820RQ - LED THERMOSTAT  
ADVANCED FUNCTIONS  
C820RQ is a room thermostat that allows the temperature setpoint adjustment in ON/OFF or TPI modes.  
OPTIMISATION  
When the thermostat is set in ON/OFF, the required setpoint temperature can be achieved by acting on the on/off times  
of the heating/cooling system according to the type of the installed system and the set differential, minimising the energy  
consumption of the system itself.  
TPI LOGIC (Time Proportional & Integral control)  
If the thermostat is power supplied at 230V, the special TPI algorithm can be used. In this control mode, the thermostat  
reaches the setpoint with accuracy and precision to maintain a more constant level of comfort, while guaranteeing the  
shortest possible switch-on time.  
According to a number of settable parameters, such as the energy class of the flat, the type of emission terminal, the  
proportional band, the regulation period and the room temperature, the C820RQ optimises the system's working time with a  
proportional and integral action.  
The output is always a single contact but controlled over the time. As soon as the room temperature reaches the setpoint  
temperature, the thermostat switch-on time decreases in every period. In this way the TPI control reduces boiler starts and  
maintains a more constant comfort level around the required setpoint. This allows a better comfort and cost savings for the  
end-user.  
It is also possible to access two different menus for configuring certain parameters:  
USER MENU  
- Password setting  
- Stand-by time  
- Display light intensity  
- Offset to correct the temperature  
- Season (summer/winter)  
- Firmware release version  
ADVANCED MENU  
- Winter season: minimum and maximum set point value  
- Summer season: minimum and maximum set point value  
- Antifreeze setting  
- Data displayed on the homepage  
- ON/OFF - TPI control function  
- Optimisation for the ON/OFF function  
- Static differential  
- Anti-seize pump  
- Virtual relay  
- Energy class for the TPI function  
- Emission terminal for the TPI function  
- TPI adjustment period  
- TPI proportional band  
- Device reset  
4
GeneralDetails
NameFantini Cosmi C820RQ LED Thermostat User Manual
MakeFantini Cosmi
LanguageEnglish
FiletypePDF (Download)
File size0.2 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Fantini Cosmi CH180-230V Touch Screen Programmable Thermostat Instructions
Fantini Cosmi CH180-230V Touch Screen Programmable Thermostat Instructions
Fantini Cosmi CH121E Flush Mounting Thermostat User Manual
Fantini Cosmi CH121E Flush Mounting Thermostat User Manual
Fantini cosmi C820RQ Dual Power Room Thermostat Instruction Manual
Fantini cosmi C820RQ Dual Power Room Thermostat Instruction Manual
Fantini Cosmi C800WIFI Programmable LED Thermostat Instruction Manual
Fantini Cosmi C800WIFI Programmable LED Thermostat Instruction Manual
Fantini Cosmi CH141E Battery Operated Weekly Programming Thermostat Owner’s Manual
Fantini Cosmi CH141E Battery Operated Weekly Programming Thermostat Owner’s Manual

Fantini Cosmi C820RQ LED Thermostat User Manual