Wall mounting
Please note!
Switches (sliders) for additional settings
LED light indications
The status of the thermostat is determined by the LED, illuminating in the
following colors:
During wire connections procedure, please make sure they are not connected to
the 230V AC power supply.
- red
- blue
1
2
A detailed explanation of the meaning of the LED lights can be found
in the table below:
Additional functions of the ESIMPLE230W / ESIMPLE230B thermostats can be
switched on or off by switches, which are located on the front cover, under the knob.
Refer to the table below to understand what these features are:
LED DIODE
EXPLANATION
Take off the knob.
Unscrew the screw placed under the knob.
Thermostat sends a signal for heating (the thermostat
gives 230V at the SL output).
Solid red
3
4
Upper slider*
HEAT
Function
Heating mode
Cooling mode
Function
Slider position
Slider position
Thermostat sends a signal for cooling (the thermostat
gives 230V at the SL output).
Solid blue
Off
COOL
Temperature has been reached or no power supply.
Bottom slider**
SPAN
Hysteresis ( 0.5°C)
TPI Algorithm
Take off the front cover of the thermostat, as shown in the picture. Connect the
thermostat as shown in the connection diagram above (see blue arrow). Then
attach it to the wall using the supplied mounting screws through the holes
provided (see red arrows).
TPI
Technical informations
Selecting the heating or cooling mode*
Power supply
Max load
230V AC 50Hz
3(1) A
5
The heating or cooling mode is based on the setting of the switches (sliders),
which are located under the knob on the front cover. The position of the
HEAT slider indicates the heating mode. When heating is required, a red
LED lights up and the thermostat gives a voltage of 230V at the SL output.
The position of the COOL slider indicates the cooling mode. When cooling is
required, a blue LED lights up and the thermostat gives 230V at the SL output.
When the thermostat is not in work mode, the LEDs are turned off.
Temperatur control range
5 – 30°C
Control method
Communication
Output signal
TPI or Hysteresis ( 0.5°C)
Wired
230V AC
Operation algorithm selection**
The thermostat gives a possibility to choose the mode of controlling the room
temperature by TPI algorithm or by hysteresis +/-0.5°C. The TPI
algorithm is designed for underfloor heating (for heating systems with high
inertia) – to precisely maintain the room temperature.
IP protection class
Dimensions
IP30
Put the front cover back in place and screw both parts together. Insert the knob
paying attention to the attachment method. Thermostat is ready to use. You can
set the temperature using the knob.
80 x 80 x 22 mm
| General | Details |
|---|---|
| Name | ENGO CONTROLS ESIMPLE230W Non-Programmable Wired Thermostat User Guide |
| Make | ENGO CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.15 MB |

ENGO Controls EONE230W Internet Controlled Thermostat User Guide

ENGO CONTROLS EFAN-230W Fan Coil Thermostat User Guide

ENGO CONTROLS FAN-24W 24V Fan Coil Thermostat User Guide

ENGO CONTROLS EASY230W Non-Programmable Wired Thermostat User Guide

ENGO CONTROLS EONE230 Internet Controlled Thermostat User Guide

ENGO CONTROLS EONEBATW, EONEBATB Internet Controlled Thermostat User Manual

ENGO Controls E901WIFI Internet Wireless Thermostat User Guide

ENGO CONTROLS EONE-BATW, EONE-BATB Internet Controlled Thermostat User Guide

ENGO CONTROLS EFAN-24W Fan Coil Thermostat User Guide

ENGO CONTROLS EFAN-230W WIFI 230V Fan Coil Thermostat User Guide