EcoNet UETST800SYS Smart Thermostat User Guide
Settings (con’t)
Settings
Humidity Settings (Menu > Settings > Humidity)
Control your home’s humidity settings for more ideal comfort.
Basic
Away
Time
Humidity
Fan
Vacation
BACK
Installer
Dehumidification
Dehumidification (Menu > Settings > Humidity)
Enable Dehumidification?
Dehumidify Set Point
Over-Cooling Amount
Yes
52 %
0 ºF
Enable Dehumidification – The system will attempt to reduce humidity in
cooling mode by reducing fan speed and over-cooling the space (when allowed
by the Over-Cooling setting). The system will only reduce airflow if the room
temperature is within one degree of set point, otherwise, full cooling airflow will
be performed.
Dehumidify Drain Timer
5 min.
BACK
HUMIDIFICATION
Dehumidify Set Point – The indoor relative humidity to be controlled to while
in cooling mode.
Over-Cooling Amount – The system will activate cooling, and possibly over-
cool the space by the desired number of degrees to improve dehumidification
performance in an effort to reach the dehumidify set point. The factory setting for
over-cooling is zero (no over-cooling) and can be adjusted up to 5 degrees of
over-cooling.
Dehumidify Drain Timer – At the end of a cooling cycle, if set, the
continuous fan setting will be turned off for the selected amount of time in order to
drain water from the indoor coil.
Humidification
Humidification (Menu > Settings > Humidity > Humidification)
Enable Humidification – The system can control a humidifier attached to the
furnace or air handler to increase humidity in the space. It is important to note you
cannot humidify above the dehumidification set point.
Enable Humidification?
No
30 %
Humidify Set Point
Humidify During...
Heat
Off
Smart Control
Off
Humidity With Fan
BACK
Humidification Set Point – This setting allows you to choose the indoor
relative humidity desired, under which humidification will activate. The default is
humidification set point is 30% and is configurable between 15 and 45%.
Humidify During – Select the modes in which humidification will be
performed. Humidification can occur during heating, continuous fan and/or
cooling mode.
• Heat – Humidifier will operate with equipment during Heat if a
humidification demand is present.
• Heat/Fan – Humidifier will operate with equipment during these modes if a
humidification demand is present.
• Heat/Fan/Cool – Humidifier will operate with equipment during these
modes if a humidification demand is present.
EcoNet® Smart Thermostat User Guide 14
> Return to Table of Contents