Home > EcoNet > EcoNet UETST800SYS Smart Thermostat User Guide

EcoNet UETST800SYS Smart Thermostat User Guide

Furnace Settings (con’t)  
Two auxiliary inputs (AUX1 and AUX2) are provided on the communicating  
gas furnace control for external control of the system (see the furnace installation  
instructions for additional details). These inputs can be configured as normally  
closed or normally open when used in conjunction with the AUX Common. These  
inputs can be used for field accessories such as smoke detectors, freeze stats, etc.  
The inputs are configured by the installer  
as follows:  
AUX Input #1 or 2 Configured – N.O. (Normally Open) or N.C. (Normally  
Closed): setting to activate the input to the furnace control IFC (see the furnace  
installation instructions).  
- If Normally Open is selected, when the AUX #1 or 2 input is connected to AUX  
Com by a closed switch (e.g. drain switch, freeze switch, etc.) the user selected  
actions will occur.  
- If Normally Closed is selected, when the AUX #1 or 2 input is disconnected to  
AUX Com by an open switch the user selected actions will occur.  
User Selected Action:  
• Off (This is the default setting. These inputs are turned off)  
• Float Switch Alarm (shutdown cooling with an active alarm)  
• Shutdown (This shuts indoor and outdoor units down, no alarm)  
• Shutdown Cool (In cooling mode this shuts down the outdoor unit,  
no alarm)  
• HP Heat Lockout (In heating mode this shuts down the outdoor unit,  
no alarm)  
• Furnace Heat Lockout (In heating mode this shuts down the gas furnace,  
no alarm)  
Furnace Settings  
Media  
Filter Type – Media, Electronic Air Cleaner (EAC) or both. The filter type  
selected will drive the air filter service reminder experience.  
Filter Type  
Fuel Type  
Natural Gas  
Elevation (feet)  
US, CN 0-2000  
Fuel Type – Natural gas or propane.  
Note: This only adjusts the EcoNet Smart Thermostats control settings and does not convert the actual  
Gas Furnace to operate with Propane. You must use the proper orifice kit for the model  
Furnace installed.  
BACK  
Elevation – This is the elevation at or above sea level.  
EcoNet® Smart Thermostat User Guide 29  
> Return to Table of Contents  
GeneralDetails
NameEcoNet UETST800SYS Smart Thermostat User Guide
MakeEcoNet
LanguageEnglish
FiletypePDF (Download)
File size6.47 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EcoNet RETST800SYS Smart Thermostat User Guide
EcoNet RETST800SYS Smart Thermostat User Guide

EcoNet UETST800SYS Smart Thermostat User Guide