Decdeal HY607 WIFI Digital Heating Thermostat User Manual
High temperature
protection temperature
difference setting
Window function
triggers temperature
Window function
running time
Programmable
AB
AC
1-9°C
2°C
5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options
choose model of you need, under power on state, long press
for 3-5 seconds enter into programming
10-20°C,setting temperature is 10°C,decrease
it ,will display【--】,then canceled this function
--
mode setting, then short press
choose: hour,minute, time period, and press
and
to adjust
data, finished setting, about 10 seconds will automatic save and exist.
AD
AE
10-20min
10
Restore factory defaults
Display Ao , long press
key to whole show
Advanced option B
Wake up
Leave home Back home
Leave home Back home
Sleep
Power off state, long press
for 3-5 seconds to access advanced option B.
or , short press
option.Remain about 5 seconds after finish setting will quit setting.
11:30
13:30
17:00
22:00
6:00 20℃ 8:00 15℃
15℃
15℃
15℃
15℃
short press
to choose the option, and adjust data by
to switch next
The optimum comfort temperature is 18℃-22℃.
NO
Setting Options
Data Setting Function
Factory Default
N1:Internal sensor (high temperature protection
close)
N2:External sensor (high temperature protection
close)
N3:Internal sensor control temperature ,external
sensor limit temperature (external sensor detect
the temperature is higher than highest
temperature ofexternal sensor, thermostat will
Close relay,turn off load)
Advanced option A
Power off state, long press
for 3-5 seconds to access advanced option A.
to choose the option, and adjust data by or , short press
switch next option.Remain about 5 seconds after finish setting will quit setting.
From A1 to AE, short press
to
Options of sensor
control
BN
N1
NO
Setting Options
Measure Temperature
Calibration
Data Setting Function
-9-+9℃(Displayed as the corrected room
temperature value)
Factory Default
A1
-1
Start/stop working
temperature difference
setting
Children lock setting
Power on/off state
A2
A3
0.5-2.5℃
1℃
0: Disable descaling function
Descaling
function
BC
Bo
0
1: Enable descaling function
0:half lock 1:full lock
0:Thermostat on/off with memory whenel
0
0
product
Can’t be changed
memory after electricity ectrify
information
A4
cut
1:Thermostat off when electrify
2:Thermostat on when electrify
Return difference: limit valve of external sensor is 45℃ for factory default (A6),value of external
sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will
remind high temperature production alarm. If temperature decline to 43℃relay continue to work and
heating alarm will be relieved. (it can be operated ,only when room temperature is lower than setting
temperature )
A5
A6
Standby bright
0: Off 1: Weakly bright 2: Brighter
2
0
0: 5+2
1: 6+1
2: 7
Weekly programming
selection
Setting temperature
minimum limit
Setting temperature
maximum limit
Sensor fault display:please choose correct working way of built-in and external sensor, if choose
wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop
heatinguntil the fault is eliminated
Warranty:
We offer the warranty of 24 months, from the sales day. The products of our company can have
A7
A8
1-10°C
5°C
20-70°C
35°C
1-10°C
Low temperature
protection
lifetimewarranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the
after-saleservice.
A9
AA
When setting temp = 10℃, if press
display 【--】, cancel low temperature protection
20°C-70°C
When setting temp =20°C, , if press
display 【 -- 】 , cancel high temperature
protection
will
5°C
High temperature
protection for external
sensor
will
45°C