Home > Decdeal > Decdeal HY607 WIFI Digital Heating Thermostat User Manual

Decdeal HY607 WIFI Digital Heating Thermostat User Manual

High temperature  
protection temperature  
difference setting  
Window function  
triggers temperature  
Window function  
running time  
Programmable  
AB  
AC  
1-9°C  
2°C  
5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options  
choose model of you need, under power on state, long press  
for 3-5 seconds enter into programming  
10-20°C,setting temperature is 10°C,decrease  
it ,will display--,then canceled this function  
--  
mode setting, then short press  
choose: hour,minute, time period, and press  
and  
to adjust  
data, finished setting, about 10 seconds will automatic save and exist.  
AD  
AE  
10-20min  
10  
Restore factory defaults  
Display Ao , long press  
key to whole show  
Advanced option B  
Wake up  
Leave home Back home  
Leave home Back home  
Sleep  
Power off state, long press  
for 3-5 seconds to access advanced option B.  
or , short press  
option.Remain about 5 seconds after finish setting will quit setting.  
1130  
1330  
1700  
2200  
600 20800 15℃  
15℃  
15℃  
15℃  
15℃  
short press  
to choose the option, and adjust data by  
to switch next  
The optimum comfort temperature is 18-22.  
NO  
Setting Options  
Data Setting Function  
Factory Default  
N1:Internal sensor (high temperature protection  
close)  
N2:External sensor (high temperature protection  
close)  
N3:Internal sensor control temperature ,external  
sensor limit temperature (external sensor detect  
the temperature is higher than highest  
temperature ofexternal sensor, thermostat will  
Close relay,turn off load)  
Advanced option A  
Power off state, long press  
for 3-5 seconds to access advanced option A.  
to choose the option, and adjust data by or , short press  
switch next option.Remain about 5 seconds after finish setting will quit setting.  
From A1 to AE, short press  
to  
Options of sensor  
control  
BN  
N1  
NO  
Setting Options  
Measure Temperature  
Calibration  
Data Setting Function  
-9-+9(Displayed as the corrected room  
temperature value)  
Factory Default  
A1  
-1  
Start/stop working  
temperature difference  
setting  
Children lock setting  
Power on/off state  
A2  
A3  
0.5-2.5℃  
1℃  
0: Disable descaling function  
Descaling  
function  
BC  
Bo  
0
1: Enable descaling function  
0:half lock 1:full lock  
0:Thermostat on/off with memory whenel  
0
0
product  
Can’t be changed  
memory after electricity ectrify  
information  
A4  
cut  
1:Thermostat off when electrify  
2:Thermostat on when electrify  
Return difference: limit valve of external sensor is 45for factory default (A6),value of external  
sensor control return difference (A3) is 2. when temperature rise to 45,then relay stop working and will  
remind high temperature production alarm. If temperature decline to 43relay continue to work and  
heating alarm will be relieved. (it can be operated ,only when room temperature is lower than setting  
temperature )  
A5  
A6  
Standby bright  
0: Off 1: Weakly bright 2: Brighter  
2
0
0: 5+2  
1: 6+1  
2: 7  
Weekly programming  
selection  
Setting temperature  
minimum limit  
Setting temperature  
maximum limit  
Sensor fault display:please choose correct working way of built-in and external sensor, if choose  
wrongly or sensor fault (breakdown), E1or E2will be displayed on the screen. Thermostat will stop  
heatinguntil the fault is eliminated  
Warranty:  
We offer the warranty of 24 months, from the sales day. The products of our company can have  
A7  
A8  
1-10°C  
5°C  
20-70°C  
35°C  
1-10°C  
Low temperature  
protection  
lifetimewarranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the  
after-saleservice.  
A9  
AA  
When setting temp = 10, if press  
display --, cancel low temperature protection  
20°C-70°C  
When setting temp =20°C, , if press  
display -- , cancel high temperature  
protection  
will  
5°C  
High temperature  
protection for external  
sensor  
will  
45°C  
GeneralDetails