Home > Danfoss > Danfoss TP5001B Programmable Room Thermostat User Guide

Danfoss TP5001B Programmable Room Thermostat User Guide

Display & Navigations  
Symbols  
Function description  
Symbols Function description  
Mon – Sun Current set day  
Schedule mode  
1
2
3
4
Current on/off period  
Holiday mode  
Current set time /  
parameter number in  
setup  
RF Status  
(TP5001RF only)  
AM  
PM  
Easy User Guide  
Battery low indicator  
(TP5001B & TP5001RF only)  
Room temperature  
TP5001  
Programmable Room Thermostat  
Temperature indication  
Power on/off  
Timer and program  
operation  
Set temperature  
SET  
Mode change / option  
setting  
Heating active  
M
BC337370422703en-000102 | 087R1003  
Temperature / option  
setting selectors  
Frost protect active  
Setting/Changing the Temperature  
What is a programmable room thermostat?  
a. Press or at any time to change the desired temperature value. SET is shown  
in the display.  
A programmable thermostat allows you to set times at which you want you  
heating to be at a specific temperature. A room thermostat works by sensing the  
air temperature and switching on the heating when the air temperature falls below  
the thermostat setting, switching it off once this set temperature has been reached.  
The TP5001 programmable room thermostat has made intelligent heating control  
easier than ever before.  
b. When releasing the or , after around 5 seconds, the display returns to  
showing the actual temperature. This temperature change is only temporary and  
will be maintained only until the next programmed setting.  
Holiday Mode  
Setting Time and Date  
Holiday Mode selects the comfort temperature typically when the home is  
unoccupied  
a. Press button , the screen will change to show the current year.  
b. Adjust using or to set the correct year. Press to accept. Repeat step b to set  
month and time settings.  
a.Press M to enter into Holiday mode and will be displayed.  
b. Holiday mode temperature can be set in User settings, 07.  
c. Press M again to exit Holiday mode.  
Advanced Programmable Timer  
The Advanced Programmable Timer mode enables the setting of a timer-controlled  
program for automatic comfort temperature, and an energy-saving lower setback  
temperature if standard room comfort temperature is not required.  
Example below for 5/2 day setup, 4 Temperature settings  
The function consists of 2 programs:  
Frost Protection Temperature  
a. The thermostat is turned OFF (Standby) mode by pressing . In OFF (Standby)  
mode the thermostat is set to Frost Protect temperature setting and will switch  
the output On if the measured temperature falls below the frost protection  
temperature setting.  
P1 with 4 events over weekdays (Mon. To. Fri.)  
P2 with 4 events over weekends (Sat. Sun.).  
b. Frost protect icon and current temperature will be display.  
P2: Sa. Su. are now shown in the display.  
P1: Press once to activate product.  
The press for 3 seconds to display  
Mo. Tu. We. Th. Fr.  
User Settings  
a. Press M button once to illuminate screen, next press M for 6 seconds to enter the  
User setting mode. Press M for parameter selection and set the parameter range  
via or . Complete all adjustments.  
P2, Event 1:  
P1, Event 1:  
1. Use or to select the start hour.  
2. Press to accept the setting.  
3. Use or to set the minute.  
4. Press to accept the setting.  
5. Use or to select the temperature.  
6. Press to accept the setting.  
1. Use or to select the start hour  
2. Press to accept the setting.  
3. Use or to set the minute.  
4. Press to accept the setting.  
5. Use or to select the temperature.  
6. Press to accept the setting.  
b. To exit press , automatic exit after 20 seconds when no button is pressed.  
No.  
Parameter settings  
Settings range  
01: Manual  
Default  
01  
Working mode  
02: Schedule timer 5/2 day  
03: Schedule timer 24hr  
02  
P1, Event 2–4:  
Repeat the Event 1 procedure  
for programming Events 2–4.  
P2, Event 2–4:  
Repeat the Event 1 procedure  
for programming Event 2–4.  
01: On/off load compensation  
02: On/off standard  
02  
03  
Heat control mode  
01  
01  
01: Normal start control  
02: Delayed start control  
03: Optimised start control  
Heat control start-up  
mode  
If the working mode is set to 24hr, only P1 program will be available (same times  
each day of the week), to change this see the User settings section of this document.  
04  
05  
06  
07  
Temperature limit high  
Temperature limit low  
Frost protect temperature  
Between low (05) and 35° C  
Between 5° C and high (04)  
Between 5° C and 15° C  
35° C  
5° C  
Display and Navigation Details  
5° C  
Holiday mode temperature Between low (05) and high (04)  
18° C  
01: 24hr  
08  
09  
10  
Timer display  
02: 12hr  
24hr  
Service due setup  
Installer setting only  
00: RF pairing mode off  
01: RF pairing mode on  
RF Pairing (TP5001RF only)  
00  
01  
01: On  
02: Off  
11  
Auto daylight saving  
Danfoss A/S  
Heating Segment • danfoss.com • +45 7488 2222 • E-mail: heating@danfoss.com  
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed ma-  
terial. Danfoss reserves the right to alter its products without notice. This also applies to products already  
on order provided that such alterations can be made without subsequential changes being necessary in  
specifications already agreed.  
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logo-  
type are trademarks of Danfoss A/S. All rights reserved.  
087R1003  
© Danfoss | FEC | 09.2020  
GeneralDetails
NameDanfoss TP5001B Programmable Room Thermostat User Guide
MakeDanfoss
LanguageEnglish
FiletypePDF (Download)
File size0.35 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss RET1000 Series Electronic Thermostat User Guide
Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss TP5001B Programmable Room Thermostat User Guide
Get the free PDF manual for the Danfoss TP5001B Programmable Room Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Danfoss TP5001B Programmable Room Thermostat User Guide Overview

Summary of Contents

  • Page 1: Display & Navigations Symbols Function description Current set day Schedule mode Current on/off period Holiday mode Current set time / parameter number in setup What is a programmable room thermostat? Holiday Mode selects the comfort temperature typically when the home is unoccupied The Advanced Programmable Timer mode enables the setting of a timer-controlled program for automatic comfort temperature.