Danfoss 088U0211 Public Room Thermostat Instructions
Instruction CF-RP Public (Tamperproof) Room Thermostat
GB
5. Uninstallation
Activate Uninstall mode on Master Controller
- fig. 1
• Use the Menu selection button to choose the
Uninstall menu. Uninstall LED flashes
• Activate Uninstall mode by pressing OK
Uninstall LED goes ON
.
Deselect output on Master Controller
• Select output to be removed by output selection
button
• Remove flashing output with OK
6. Specifications
Temperature setting range
Transmission frequency
5-35°C
868.42MHz
Transmission range in
normal buildings (up to)
30m
Transmission power
Battery
< 1mW
Alkaline 2xAA, 1.5V
3-4 years
0-50°C
Battery lifetime (up to)
Ambient temperature
IP class
21
VI.UH.P5.1C
Produced by Danfoss Floor Heating Hydronics 08.2009
7
| General | Details |
|---|---|
| Name | Danfoss 088U0211 Public Room Thermostat Instructions |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.39 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide