switching will remain valid from the time of PROG switching to the time  
of next switching (PROG ).  
The time of PROG switching is 00:00 that cannot be modified, only  
the temperature assigned thereto can be changed to meet individual  
requirements. In default setting the thermostat carries on only 1 switching  
(PROG ) every day, which is valid from 00:00 to 00:00 on the following  
day.  
Remark: 1 switching a day (factory default setting) only makes sense  
if you need uniform temperature all day. (For example, if you want  
to maintain a continuous economical temperature, e.g. 16 °C, on  
weekdays, while you wish to maintain a comfort temperature, e.g. 22  
°C, on weekend days). In other cases, it is advisable to activate several  
switchings a day for comfort and energy-saving reasons. Considering  
energy savings, it is recommended that the comfort temperature is  
activated only during the periods when the room is being used, because  
lowering the room temperature by 1 °C will result in approx. 6 percent  
energy savings on average during a heating season.  
In default position PROG PROG  
switchings are inactive (their  
- 24 -  
GeneralDetails
NameCOMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual
MakeCOMPUTHERM
LanguageEnglish
FiletypePDF (Download)
File size1.2 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
COMPUTHERM E800RF Multizone Wi-Fi Thermostat Instruction Manual
COMPUTHERM Q5RF Multi Zone Wireless Digital Room Thermostat Instruction Manual
COMPUTHERM Q5RF Multi Zone Wireless Digital Room Thermostat Instruction Manual

COMPUTHERM Q20 Programmable Digital Room Thermostat Instruction Manual