Temperature Unit Change  
While in cool+heat mode, a 15 minute ꢀmer  
(auto change-over ꢀmer) will prevent the  
opposite HVAC mode from operaꢀng if the  
set temperature and room temperature  
remain within 2° F. This ꢀmer is automaꢀcally  
disabled upon changing the HVAC mode, fan  
mode, or set point temperature.  
The thermostat can display temperature in  
either Fahrenheit or Celsius. To change the  
temperature units, press and hold the knob  
unꢀl the display changes (4 seconds). The  
display will show the current temperature,  
the set point temperature (if it was previously  
displayed), and the temperature units opꢀons  
with the currently selected units blinking.  
Rotate the knob to change the selecꢀon.  
Upon selecꢀng units, the temperature(s)  
displayed will update values accordingly.  
Once the desired units are blinking, press the  
knob to accept the changes.  
Elec Heaꢀng Mode  
When in elec heaꢀng (heat pump) mode  
some extra rules are applied. If the elec  
heaꢀng mode is selected and the current  
temperature ever reaches 5° F below the set  
point temperature, the gas heat mode will  
turn on in conjuncꢀon with the elec heat.  
When the gas heat must turn on to assist the  
elec heat, the elec heat gets a strike. Once the  
elec heat gets three strikes and that heaꢀng  
cycle has completed, it is disabled for 1hr and  
45 minutes. When the elec heat is disabled in  
this way, the gas heat becomes the primary  
source of heat. Aſter 1 hr and 45 minutes, the  
elec heat becomes the primary source again.  
If the elec heat gets a strike but completes a  
heaꢀng cycle without the assistance of the  
gas heat, the elec heat will lose a strike. If the  
elec heat is running for 20 minutes without  
the gas heat needing to turn on, the strike  
counter is reset. Whenever the gas heat is  
running in this mode, the ‘Elec’ segment will  
flash.  
Retained Seꢁngs  
Some seꢁngs will be retained when power is  
lost, or the thermostat is rebooted.  
The retained seꢁngs include:  
•
set points - Three set points are  
retained: one for cool, one for heat,  
elec (electric) heat and gas heat and  
one for cool+heat.  
•
temperature units.  
Seꢁngs are stored automaꢀcally upon any  
changes made to any set point or  
temperature unit change.  
HVAC Mode Descripꢀons  
The table below describes which outputs are  
live by the thermostat in the specified HVAC  
mode.  
Compressor/Elec Heat Short Cycle Protecꢀon  
(DOB)  
HVAC  
To protect the compressor/heat pump from  
short cycling, a 3 minute delay will be  
iniꢀated for both the compressor and elec  
heat outputs aſter either output’s demand is  
saꢀsfied. During this 3 minute delay, if there  
is a demand for the compressor or elec heat,  
the HVAC state segment will blink according  
to the selected mode. Once the delay has  
expired, the thermostat will resume normal  
operaꢀon.  
Live Outputs  
Mode  
HVAC outputs are disabled,  
fan is based on selecꢀon  
Off  
Compressor and selected  
fan speed  
Electric heat and gas heat  
Cool  
Elec Heat  
Gas Heat  
Heat  
Gas Heat  
Cooling Cycle: Compressor  
and selected fan speed  
Heaꢀng Cycle: Electric heat  
(when Dip switch 2 is on),  
gas heat and Fan  
Cool+Heat  
GeneralDetails
NameColeman 9420-381 Digital Wall Thermostat Instruction Manual
MakeColeman
LanguageEnglish
FiletypePDF (Download)
File size0.19 MB
Download PDF