Sleep Mode
Manual Reboot
Sleep mode is acꢀvated automaꢀcally 10
seconds aſter the last user interacꢀon. In
sleep mode the LCD will dim, and power
usage will drop. The first user interacꢀon
(rotaꢀon, knob press, or knob hold for 4
seconds) will wake up the device and brighten
the display.
The thermostat can be manually rebooted by
pressing and holding the knob for 12 seconds.
When the knob is held for 4 seconds, the
thermostat will go to the units selecꢀon
screen, aſter another 4 seconds, the
thermostat will begin a count down. Once the
countdown reaches 0 and the display turns
off, the device will wait for the knob to be
released. Upon the release of the knob, the
device reboots.
Auto Accept
If the user was changing any seꢁng (HVAC
mode, fan mode, set point, or temperature
units) and the knob was not pressed to accept
the current selecꢀon, the thermostat will
auto accept the current selecꢀon aſter 7
seconds and apply any changes.
Set Temperature Range
Temperature
Range
Mode
°F
33° F to 99° 1° C to 37°
°C
Cooling (set)
Heaꢀng (set) 33° F to 99° 1° C to 37°
If the current temperature is below 33° F (0°
C), the display will show “LO” and if the
temperature is above 99° F (37° C), the
display will show “HI”.