Low Voltage Thermostat  
7days 4 time periods scheduling. Set the target heating  
and cooling temperature respectively.  
User Guide  
ModelTP808-S  
Both Vacation mold and hold duration mode available  
for comfort and energy saving  
Temperature display of Celsius or Fahrenheit scale  
Home screen quick reference  
Energy saving  
Lock  
Week  
WIFI  
Hold mode  
Time  
System Mode  
Time Periods  
Room Temp  
About your new thermostat  
Comfirm button  
Running Mode  
Reminder Symbols  
Set Temp  
This thermostat is used to control system,  
EM heat activation, adjustable  
Compressor delay  
Fan  
compressor delay time and O/B changeover. It is  
with tempered touch sensitive button, quick  
connecting terminals to save installer’s time. 7  
days programmable and four modes everyday  
make users’ life convenient and comfortable.  
Fan mode display  
Operation  
:Switching System Mode  
Thermostat passed FCC standard.  
Short press button to select system mode:  
HEAT,COOL,AUTO,EMER,OFF.  
:Comfirm button  
Thermostat box you will find  
Press this button to comfirm your settings.Press again  
select SchedulePermanent Hold and Energy saving  
:Fan Mode  
Thermostat  
Manual  
Screws  
QC pass certificate  
Press this button to select fan on,auto and cycle  
Setting the time  
When connecting the thermostat to Wi-Fi, the  
time will sync automatically. If not  
Service  
connecting to Wi-Fi,Press  
Auto Mode  
Short press button to select Auto.Short press button  
to enter AUTO mode  
to set second-hour-week  
We offer the warranty of 18 months from the sales day.  
If it is not the problem of quality or beyond the warranty  
time, we will charge for the after-sale service.  
:Setting the Lock  
Press and hold button at the same time over  
7seconds to lock/unlock your thermostat  
Technical Data of your thermostat  
SensorNTC3977 10K Accuracy:±1℉  
WIFI reset  
Long press  
Temp. Range41-95Power Consumption:<1.5W  
Timing error:<1%  
Power SupplyAC24V, 50 ~60Hz  
Shell MaterialPC Fireproof)  
Dimension132x90x23.5mm  
seconds to reset WIFI when power off  
Check external sensor temperature  
(external sensor only)  
Press and  
to check external sensor temperature  
Installation boxUS Standard box  
Ambient Temp.0 ~ 113,  
5 ~ 95RH(Non condensing)  
Storage Temp:-41~ 140℉  
Setting a Schedule  
When connecting the thermostat to Wi-Fi, the schedule  
is programmed based on time and temperature set points  
from the Sensi app. If you are not connecting to Wi-Fi,  
follow these steps to set a basic 7 day schedule with 4  
mandatory set points.Long press  
7secends to enter weekly program funtion.Short  
press button to set week-hour-cool temperature-heat  
button above  
Features of your thermostat  
temperature ,Short press  
the parameters Long press  
7seconds to go back factory weekly program settings  
to return back.Press+/- to set  
at the same time over  
Apply with various kind of heating and cooling system.  
Including Single stage, Multi-stage And Heat Pump  
(Up to 3-stage heat, 2-stage cool, with Aux.  
Or Emergency heat)  
Wireless WiFi: APPs for iOS and Android devices.  
Voice control: Work with Amazon Echo and Google  
Assistant.  
Example Schedule  
Period  
Sleep  
22:00  
Get up  
6:00  
Go outside  
8:00  
Go home  
18:00  
Week  
Time  
Mon-Sun Cool Temp  
83  
83  
79  
79  
Heat Temp  
72  
61  
72  
61  
4’’ LCD display with backlight  
GeneralDetails
NameWengart TP808-S-2 Low Voltage Thermostat User Guide
MakeWENGART
LanguageEnglish
FiletypePDF (Download)
File size0.89 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Wengart TP808-3 7 Day Programmable Thermostat User Manual
Wengart TP808-3 7 Day Programmable Thermostat User Manual
Wengart TP808-3 Heat Pump Thermostat User Guide
Wengart TP808-3 Heat Pump Thermostat User Guide
Wengart TP808 Low Voltage Thermostat User Guide
Wengart TP808 Low Voltage Thermostat User Guide
Wengart TP808 Wi-Fi Low Voltage Thermostat User Guide
Wengart TP808 Wi-Fi Low Voltage Thermostat User Guide
Wengart WG603 Home Smart Thermostat User Guide
Wengart WG603 Home Smart Thermostat User Guide

Wengart TP808-S-2 Low Voltage Thermostat User Guide
Get the free PDF manual for the Wengart TP808-S-2 Low Voltage Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Wengart TP808-S-2 Low Voltage Thermostat User Guide Overview

Summary of Contents

  • Page 1: Low voltage thermostat 7 days 4 time periods scheduling. Set the target heating and cooling temperature respectively. Both vacation mode and hold duration mode available for comfort and energy saving. Temperature display of Celsius or Fahrenheit scale. This thermostat is used to control the system, EM heat activation, adjustable compressor delay, fan compressor delay time, and O/B changeover. 7 days programmable and four modes every day make users’ life convenient and comfortable. Thermostat passed FCC standard. We offer the warranty of 18 months from the sales day. Setting a schedule when connecting the thermostat to Wi-Fi is programmed based on time and temperature set points from the Sensi app. Apply with various kinds of heating and cooling systems, including single stage, multi-stage, and heat pump. Wireless WiFi: apps for iOS and Android devices.
  • Page 2: Short press fan button to select cycle. If you want to circulate the air in your home using your indoor blower fan, you can set this feature at the thermostat. A percentage is selected to indicate how often the fan should run each hour, you can set 5% increments from 10% – 100%. Select UV lamp replacement run time. The thermostat will display “Chg UV” when UV time reaches the set limit. This is the reminder of replacement run time of Chg pad. The thermostat will display “Chg Pad” when Chg pad reaches the set limit. This is the reminder of replacement run time of Chg Filter. The thermostat will display “Chg Filter” when Chg Filter reaches the set limit. WARNING: Please arrange the professional technician to install this product according to installation drawing and instruction.