VEVOR ET-72G Programmable Thermostat Instruction Manual
Troubleshooting
E1: Built-in probe failure, please contact your dealer or professional
technician.
E2: External probe failure, please contact your dealer or professional
technician.
Installation
1.Loosen the bottom screw by a Phillips screwdriver. Then open the
thermostat from the upper right side as shown.
Note: Screw the nut out of the groove and do not need to unscrew it.
2.Wire as shown:
L/N lead: Connect the power cord using the terminal block.
L1/N1 lead: Use a terminal block to connect the load line.
IN/SNR terminal: Connect the floor sensor.
OUT terminal:Connect to IN/SNR of Power Module.
Note:Disconnect the main power supply before wiring. If an electric floor
heating cable or mat system requires more than 15 Amps, install a power
module. Wiring diameter: 12 to 22 AWG.
- 12 -
| General | Details |
|---|---|
| Name | VEVOR ET-72G Programmable Thermostat Instruction Manual |
| Make | VEVOR |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.19 MB |