P05 - Temperature Offset  
P08 - Program Mode  
If your thermostat is in an area of your suite that is  
colder or warmer than the rest of your home, you  
can offset the thermostat's temperature reading to  
compensate. Before you adjust this setting, you will  
need a thermometer (inexpensive options can be found  
in any hardware store) to measure the temperature near  
your thermostat, and again in a room that feels similar  
to the rest of your suite. The difference in temperature  
is what you need to offset your thermostat at. Your  
thermostat can be offset +/- 5 °C or 10 °F.  
To save energy and live comfortably, your thermostat  
allows you to program up to four scheduled  
temperatures in each day. There are three types of  
programs available:  
7-Day Program - set a unique schedule for each day  
of the week  
1-Day Program - set one schedule that is used every  
day of the week  
5+1+1Day Program: set one schedule for all  
weekdays with unique schedules for Saturday and  
Sunday  
To offset your thermostat temperature:  
Hold [MENU] to enter the Advance Settings menu  
Continue pressing [MENU] until reaching P05  
Press [] / [] to offset your temperature  
The default program on your thermostat is set to a 7-Day  
Program. If you would like to use this program, skip to  
part B of the following instructions.  
If you would like to use a different program mode,  
continue to part A.  
Press [SELECT] to confirm and exit the Advanced  
Settings menu  
To set a program:  
A)  
P06 - Switching Differential  
- Heat Mode  
Hold [MENU] to enter the Advance Settings menu  
Continue pressing [MENU] until reaching P08  
Press [] / [] to cycle through the following options:  
The switching differential while in heat mode refers to  
the delay in call for heating. We recommend keeping  
your thermostat at the default 2 °C (4 °F) setting,  
however you can adjust the differential between 2-4 °C  
(4-8 °F) if desired.  
Program Type  
Mode  
To change your switching differential while  
No Program  
noP  
1
in heat mode:  
1-Day Program  
5+1+1 Day Program  
7-Day Program  
Hold [MENU] to enter the Advance Settings menu  
Continue pressing [MENU] until reaching P06  
Press [] / [] to adjust your setting  
5
7
Press [SELECT] to confirm and exit the Advanced  
Settings menu  
Press [SELECT] to confirm and exit the Advanced  
Settings menu  
P07 - Switching Differential  
- Cool Mode  
The switching differential while in cool mode refers to  
the delay in call for cooling. We recommend keeping  
your thermostat at the default 2 °C (4 °F) setting,  
however you can adjust the differential between 2-4 °C  
(4-8 °F) if desired.  
To change your switching differential while  
in cool mode:  
Hold [MENU] to enter the Advance Settings menu  
Continue pressing [MENU] until reaching P07  
Press [] / [] to adjust your setting  
Press [SELECT] to confirm and exit the Advanced  
Settings menu  
18 | Installation and User Manual  