The load is disabled, oht flashes on the screen «oht»  
room or the power of the underfloor heating is not enough  
to reach the set temperature in less than 3 hours;  
Transportation of goods carried in the package, ensuring  
the safety of the product.  
POSSIBLE PROBLEMS, CAUSES  
AND WAYS TO OVERCOME THEM  
The temperature inside the housing exceeded  
85 °C and triggered protection against internal  
overheating. Every 1 sec the screen displays  
«oht».  
the transition between heating / cooling modes is  
completed, and there is not enough time for self-learning;  
The device is transported by any kind of transport (rail,  
sea, motor, air transportation).  
The thermostat does not display the PIN code. The  
blue indicator on the controller is constantly on  
the floor temperature offset has been changed, and there  
is not enough time for self-learning.  
Date of manufacture is on the back side of device.  
Application time is unlimited.  
Possible cause: inner overheating of the device to which  
can lead: bad contact in the terminals of the device, high  
ambient temperature, overwhelming power output or  
incorrectly selected cross-section of wires for connecting.  
It is necessary to: go to the «Pin» section on the  
thermostat (see Table 1). You will see a PIN code (a  
three-digit number with no additional characters).  
It is necessary to: make sure that there are no frequent  
sudden changes in the room temperature or that the power  
of the underfloor heating is sufficient to reach the set  
temperature in less than 3 hours. For the preheat function  
to operate, make sure that this function is enabled on the  
app, the thermostat is in schedule mode and enough time  
has passed for self-learning.  
The device does not contain harmful substances.  
If you have any questions or you something will not clear,  
call the Service centre the telephone number listed below.  
It is necessary to: check tension of power wires in the  
device terminals, make sure that the switching load does  
not exceed the permissible and that the cross section of the  
wires is selected correctly.  
Connection failed via Android or iOS apps, the  
indicator is blue  
The thermostat is connected to the «cloud», but the  
account is not accessed.  
Feature of protection against internal overheating: the  
device will be unlocked in case if the temperature inside will  
decrease to 75 °C. If the protection trips more than 5 times  
within 24 hours, the thermostat is blocked until the  
temperature inside the case drops to 75 °C and one of the  
buttons is pressed or after 30 minutes without pressing any  
buttons. When overheated, pressing any button will display  
the current temperature of the thermal protection sensor.  
SAFETY INSTRUCTIONS  
Heating does not turn off, the set heating temperature  
remains not reached  
It is necessary to: follow steps 8-10 to connect via the  
my.terneo desktop application.  
Carefully read and become aware of yourself these  
instructions.  
Possible cause:  
The load does not operte according to the settings,  
every 5 seconds the screen displays «OC» or «SC»  
insufficient power of the heating cable;  
Connection of the device must be done by a qualified  
electrician.  
lack or insufficient thermal insulation;  
incorrect installation of the heating cable or temperature  
sensor;  
«OC» — open of circuit of the sensor  
Do not connect 230 V mains voltage instead of the sensor  
(it leads to failure of the thermostat).  
Every 5 sec the screen displays «Ert»  
the power is not enough for the operation of the underfloor  
heating in the specified mode.  
Before the installation (dismantling) and connection  
(disconnection) of the device, turn off voltage supply and  
also act according to the «Rules of an arrangement of  
electric installations».  
Possible cause: open or short circuit of the  
internal overheating sensor. Control over inner  
overheating will not be done.  
«SC»ꢀ— short circuit of the sensor  
It is necessary to: make sure that the underfloor heating is  
installed correctly (the cable section is selected correctly, a  
sufficient level of thermal insulation of the room is made,  
the heating cable and temperature sensor are installed in  
accordance with the requirements) and that the power of  
your power supply network is sufficient for the operation of  
the underfloor heating. Otherwise, contact the service  
center.  
The temperature controller has switched to the  
Emergency Timer Mode.  
It is necessary to: send the device to the Service Center.  
Otherwise control over inner overheating will not be done.  
Do not immerse the sensor with a connecting wire in the  
liquid medium.  
Possible cause: Failed connection, damage to the  
sensor circuit, or temperature out of range (see  
Specifications).  
Do not switch the non assembled device to the network.  
When you press the buttons, it displays «Lbt»  
Turning on and off or and configure the device should be  
with dry hands.  
What should be done: check the junction of the  
temperature sensor with the thermostat and its circuit,  
check for mechanical damages along the entire length of  
the connecting wire and no power wiring that passes  
close.  
Possible cause: discharge or damage to the  
internal power supply.  
Wrong password when connecting to the WLAN  
network created by the thermostat  
Do not connect the device to the network disassembled.  
Avoid hitting of water or moisture to the device.  
It is necessary to: wait approximately 1-2 hours to charge  
the power supply or contact the service center. Otherwise,  
if there is no power in the network, the operation of the  
clock will not continue.  
It is necessary to: enter a password case-sensitive,  
language-sensitive, and number-of-character-sensitive  
DSEXXXXXX, where XXXXXX is the last six symbols in the  
name of network Wi-Fi, created by the thermostat and to  
which actual connection is being established (for example:  
DSE27001А).  
Operation in the Emergency Timer Mode: the mode will  
ensure the operation of the underfloor heating in case of  
damage to the sensor: the user selects the time of the  
work of the applied force, the rest time in the 30 –  
minutes cyclic interval the applied force will be switched  
off. The time of the work of the applied force can be  
installed in the range oFF, 1...29 minutes, on. For the  
purpose that applied force will work constantly elect  
«on», for the purpose to switch off it completely select  
«oFF».  
Do not expose the device to extreme temperatures  
(higher than 40 ºСor below -5°C) and high humidity.  
For the connected controller, the LED has stopped  
glowing blue, the state of the controller on the  
application is offline  
Never clean the device with the use of chemicals such as  
benzene, solvents.  
Do not store the device and do not use it in areas with the  
dust.  
Possible cause:  
Internet connection unavailable or provider-side issues;  
Do not attempt to disassemble and repair the device.  
Do not exceed the landmarks value adaptor and power.  
WE TAKE YOUR PRIVACY SERIOUSLY  
change of the router, its settings or its damage;  
It is necessary to:  
We’re committed to being open and honest about how we  
use data. We’ll work hard to keep your data safe and we  
always ask for permission before sharing personally  
identifiable information.  
To protect against overvoltage caused by lightning  
discharges, use a lightning protector.  
Neither indicator nor display light up upon  
thermostat switch-on  
make sure you have an available WLAN connection or  
Internet access;  
Protect the children from games with the working device,  
it is dangerous.  
in case of changing the router settings, reconnect the  
thermostat via the terneo desktop app;  
Possible reason: no power supply voltage.  
To learn more about our Privacy Policy, go to  
Required: check availability of power supply voltage  
using a voltmeter. If power supply voltage is available  
then contact the Service center please.  
until the issue is solved, you can change the temperature  
using the thermostat buttons or using the offline mode on  
the Android application.  
vF24_220728  
The thermostat does not respond to changing  
settings on the app  
Preliminary warming up out-of-service or incorrect  
operation  
ADDITIONAL INFORMATION  
Possible reason: switched on blocking of changes from  
Low Voltage Directive 2014/35/EU  
EMC Directive 2014/30/EU  
Do not fire and do not throw away the device with the  
household waste.  
«cloud».  
Possible cause:  
the function is disabled on the app Preliminary warming  
up;  
Required: go to the thermostat menu section «blc» and  
change its status to «oFF» (see Table 1, «Remote  
management blocking by thermostat»).  
After the end of its service life, the product must be  
disposed of in accordance with applicable law.  
there are often sudden changes in temperature in the  
Manufacturer and vendor: DS ELECTRONICS, LTD  
04136, Ukraine, Kyiv region, Kyiv, 1–3 Pivnichno-Syretska str.  
+38 (091) 481-91-81, Service Center: +38 (091) 481-91-81  
13  
14  
15  
GeneralDetails
Nameterneo bx Smart Thermostat Instruction Manual
Maketerneo
LanguageEnglish
FiletypePDF (Download)
File size0.35 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
terneo rzx Smart Thermostat User Manual
terneo rzx Smart Thermostat User Manual
terneo v3G33 Simple Heat Control Thermostat Instruction Manual
terneo v3G33 Simple Heat Control Thermostat Instruction Manual
terneo BeeRT Digital Thermostat Instruction Manual
terneo BeeRT Digital Thermostat Instruction Manual

terneo bx Smart Thermostat Instruction Manual