telethings teleRelays-2L Device Thermostat User Manual
Telethings
command – represents mode (ON, OFF, TOGGLE, DELAY ON ili DELAY OFF)
relay_number – represents the number of the relay output in the range 0-7,
depending on the number of relays on the device
timer_value – represents the value of the time interval to maintain the selected
relay states
PORT
NUMBER
PACKAGE
OFFSET
DATA
DATA SIZE IN BYTES
command
relay_number
timer_value
1
1
1
0
1
2
15
Table 3. Reference for creating a data formatter for a packet sent from the server to the device
5.2. Communication Flow
The teleRelays-2L device communicates with the server every 15 minutes, if no
commands have been sent from the server during that period. Also, the teleRelays-2L device
communicates with the server 6 seconds after the last successfully received and executed
command from the server.
Also, the teleRelays-2L device constantly checks whether there are new data sent from the
server.
NOTE:
If your own server is used, then it is not possible to use the Telething IoT Cloud shown in the
previous chapter. In this case, scan the QR code on the device and send us an email with the
device's serial number so that we can send you the device EUI and application key.
11
| General | Details |
|---|---|
| Name | telethings teleRelays-2L Device Thermostat User Manual |
| Make | Telethings |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.31 MB |

telethings teleRelays-2D Tele Thermostat User Manual

telethings 2D Smart LoRaWAN Thermostat User Manual

telethings TELESWITCH – 2L Smart LoRaWAN Thermostat User Manual