Home > Technolysis > technolysis HY703RF WIFI Thermostat User Manual
technolysis HY703RF WIFI Thermostat User Manual
for 1 second.
RF signal indicator (orange):power on within 10 seconds is always on (at this time you can
send the IP address of the thermostat to the receiver to complete the pairing: refer to the
advanced options of the thermostat and receiver pairing options ), pairing successfully after
this signal lights out; or 10 seconds without pairing action this light will also automatically
go out; normal operation, the receipt of wireless signals, this light flashes.
Load/fault indicator (red):When working normally, the load output open light is on, the
load output close light is off; when there is a fault, flashing alarm, the fault indication is as
follows:
1, thermostat and receiver not paired: flash 2 times (fast flash), interval out 2 seconds
2, wireless signal loss (1 hour without data communication): flash 3 times (fast flash),
interval extinguished 2 seconds
3, external sensor alarm: flash 4 times (fast flash), interval extinguished 2 seconds
Note: Fault 3 is only valid when N3 is selected for Sensor Type in the Thermostat Advanced
Options.
WIFI signal indicator (Blue) :Flash once when receiving WIFI Data; Continuous Flash
indicates the EZ distribution mode on WIFI; Continuous slow flash indicates the AP
distribution mode on WIFI; Always on when the distribution is successful; And when the
WIFI is abnormal, will flash twice, interval extinguished two seconds.
Wiring and installation instructions
1、Read these instructions carefully, failure to follow them may damage the product
or lead to dangerous situations.
2、Check the instructions and the maximum load power given in the product to
make sure the product is suitable for your application.
3、The installer must be a trained and experienced maintenance technician.
4、After installation is complete, follow the instructions in the instructions.
Attention
Working with electricity can lead to short circuits or damage to equipment and
cause personal injury!
Be sure to disconnect the power supply before installation
Wiring diagram