STELPRO ST302P Programmable Electronic Thermostat Owner’s Manual
INITIAL SETTINGS
OWNER’S
MANUAL
CONNECT THE POWER
SUPPLY WIRES
2
AND PROGRAMMING
To begin with, follow the on-screen instructions to adjust your
thermostat’s settings. Press
to confirm.
WARNING: Incorrectly connected electrical wires could
result in a fire hazard.
or
to change your selection and
PROGRAMMABLE ELECTRONIC THERMOSTAT
FOR BASEBOARDS AND CONVECTORS
• Language: FRA / ENG (Français / English)
• Temperature format: °C / °F (Celsius / Fahrenheit)
1. Complete the thermostat’s electrical connection according to
the diagram below. Tighten the wires securely in the supplied
wire connectors.
ST302P
ST402P
• Operation mode: PROG / MANUAL (Programmable / Manual).
If you selected MANUAL mode, your thermostat is now ready to
use! If you selected PROGRAMMABLE mode, configure the
following settings:
2. Push the wires and connectors into the electrical box.
– Date and time
NOTE: If the electrical wires are aluminum, use CO/ALR
connectors instead (not supplied).
– Automatic daylight savings time switchover: DST Y / DST N
(Daylight savings time Yes / Daylight savings time No)
– Program setpoint temperatures: (Wake, Leave, Return, Sleep)
– Monday to Friday program hours: [Mo-Fr] (Wake, Leave,
Return, Sleep)
– Saturday and Sunday program hours: [Sa-Su] (Wake, Sleep)
The following table shows the default program values:
WEEK DAYS
RETURN
WAKE
LEAVE
SLEEP
E
6:00 AM
21°C / 70°F
8:00 AM
16°C / 61°F
4:00 PM
21°C / 70°F
10:00 PM
17°C / 63°F
1-844-STELPRO
WWW.STELPRO.COM
WEEKEND DAYS
WAKE
SLEEP
7:00 AM
21°C / 70°F
11:00 PM
17°C / 63°F
LOAD POWER
The diagram shows a 240 V power supply.
IMPORTANT INSTRUCTIONS
THE THERMOSTAT MUST BE INSTALLED BY A CERTIFIED
ELECTRICIAN.
FEATURES
Connect the thermostat to a 120 to 240 VAC power source ONLY and
comply with load limits.
ATTACH THE THERMOSTAT
3
KEY FEATURES
1. Press
or once to lower or raise the setpoint temperature by
WARNING – HIGH VOLTAGE. Turn off the power supply before
installation and maintenance. Leave at least 12 in. (30 cm)
clearance around the thermostat to ensure that it is properly
vented.
0.5°C / 1°F. If you are in PROGRAMMABLE mode, the set-
point change will be considered as a temporary override to the
programming. The thermostat will return to PROGRAMMABLE
mode when the next program begins. To cancel the override and
1. Using the alignment guide,
hook the bottom [A] of the
thermostat into the bottom of
the plate. Be sure not to jam
the wires between the thermo-
stat and mounting plate.
return to PROGRAMMABLE mode, press
2. Press once to switch from MANUAL to PROGRAMMABLE
mode and vice versa.
.
SAVE THESE INSTRUCTIONS
2. Rotate the thermostat upwards
and attach it on the top hook of
the mounting plate.
3. If PROGRAMMABLE mode is selected, press
the next program.
twice to go to
TECHNICAL SPECIFICATIONS
TENSION ET CHARGE
ADVANCED MENU ACCESS AND USE
1. Press and hold
advanced menus.
for 3 seconds to access the thermostat’s
PRODUCT CODE
SUPPLY VOLTAGE
VOLTS
LOAD AT 120 V
WATTS
LOAD AT 240 V
WATTS
A
2. Press
or to change your selection.
ST302P
ST402P
120-240
150-1500
150-2000
300-3000
300-4000
3. Press
menu.
to confirm your selection and proceed to the next
120-240
Load control type
Frequency
Resistive
60 Hz
4. Press and hold
for 3 seconds to exit the advanced menus.
3. Tighten the screw at the top of the
thermostat [B] to hold it in place
securely.
Storage temperature
-40°C to 50°C (-40°F to 122°F)
-20°C to 50°C (-4°F to 122°F).
LC display less effective below 0°C (32°F)
ADVANCED MENU LIST
B
Operating temperature
• Language: FRA / ENG (Français / English)
4. Restore the power at the circuit
breaker.
Humidity
5% to 98% without condensation
• Temperature format: °C / °F (Celsius / Fahrenheit)
Action
Type 1.Y
• Operation mode: PROG / MANUAL (Programmable / Manual.
When PROGRAMMABLE mode is selected, you can change
the following settings:
Pollution degree
Software
2
Class A
NOTE: If you need to remove the
thermostat, follow step 1 in section
1, then use a straight screwdriver
to unhook it from the top of the
mounting plate.
Rated impulse voltage
Category II overvoltage (1500 V)
Independently mounted control for surface mounting
– Date and time
Thermistor used as a sensor, carries no load current
– Automatic daylight savings time switchover: DST Y / DST N
(Daylight savings time Yes / Daylight savings time No)
Overload protection device external to the control: circuit breaker (refer to local electrical code)
– Program setpoint temperatures: (Wake, Leave, Return,
Sleep)
– Monday to Friday program hours: [Mo-Fr] (Wake, Leave,
Return, Sleep)
BEFORE YOU GET STARTED
– Saturday and Sunday program hours [Sa-Su] (Wake, Sleep)
• Keypad lock: LOCK / UNLOCK (Lock keypad / Unlock keypad)
• Reset thermostat to default values: RST N / RST Y (No / Yes)
• The box contains one (1) thermostat with mounting plate, two (2)
mounting screws, two (2) twist-on wire connectors and one (1)
owner’s manual.
INTERFACE
• To install this thermostat, you will need a #2 Phillips screwdriver.
USING THE TECHNICAL MENUS:
This thermostat is PROGRAMMABLE. PROGRAMMABLE mode
allows you to define the setpoint temperature according to time
of day and day of the week. (See the INITIAL SETTINGS AND
PROGRAMMING section.) You can also use this thermostat in
MANUAL mode, i.e. the setpoint temperature will be constant.
• Install your thermostat about 5 ft (1.5 m) from the floor on an
inside wall facing the heating system.
1. Press
menus (the advanced menu will appear after 3 seconds but
continue to hold for another 7 seconds).
for 10 seconds to access the thermostat’s technical
2. Use
ou to change your selection.
Touch the keypad once to activate the backlight, then you can
make changes.
3. Press
menu.
to confirm your selection and continue to the next
INSTALLATION
4. Press
menus.
for 3 seconds to exit the thermostat’s technical
TECHNICAL MENU LIST
ATTACH THE MOUNTING PLATE
Heating output
1
• t1: Maximum room temperature setpoint limit (5°C to 30°C / 41°F
to 86°F). The default setting is 30°C.
• t2: Minimum room temperature setpoint limit (5°C to 30°C / 41°F
to 86°F). The default setting is 5°C.
A
WARNING: Turn off the
power supply.
Keypad locked
Week period
(Mo-Fr: Monday
to Friday, Sa-Su:
Saturday and
Sunday)
NOTE: The maximum setpoint limit must be higher than the mini-
mum setpoint limit, and the minimum setpoint limit must be lower
than the maximum setpoint limit.
Ambient
temperature/
contextual
1. Loosen the screw [A] at the
top of the thermostat without
removing it.
Menu indicator
information
• t3: Year of production
• t4: Month of production
• t5: Identification number
• t6: Software version
2. Separate the mounting plate
from the thermostat. Pull the
top of the plate and rotate.
Current program
(Wake, Leave,
Return, Sleep)
MOUNTING
PLATE
• t7: Thermostat control code
Keypad
3. Take the power wires [B] out of the junction box and
run them through the large opening in the center of the
mounting plate [C].
4. Using the two (2) mounting screws provided [D], attach the
thermostat mounting plate to the junction box. The plate
can be centered on the junction box or shifted to the left
or right.
B
D
C
JUNCTION BOX
STELPRO LIMITED WARRANTY
D
MOUNTING PLATE
STELPRO DESIGN INC. Saint-Bruno-de-Montarville, Québec, Canada, J3V 6L7
| General | Details |
|---|---|
| Name | STELPRO ST302P Programmable Electronic Thermostat Owner’s Manual |
| Make | StelPro |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.25 MB |

STELPRO STF362NP Floor Heating Thermostat Owner’s Manual
STELPRO SAT402ZB Smart Thermostat User Guide

STELPRO ST252NPFF Non-Programmable Electronic Thermostat Owner’s Manual

STELPRO ST402PFF Programmable Electronic Thermostat Owner’s Manual

STELPRO ASMC402 Maestro Zigbee Smart Programmable Thermostat User Guide

STELPRO SIBTE12C Electronic Thermostat Owner’s Manual

STELPRO STZW402+ Electronic Thermostat for The Smart Home Owner’s Manual

STELPRO SIBTE13F Electronic Thermostat User Guide

STELPRO STCP MULTIPLE PROGRAMMING ELECTRONIC THERMOSTAT User Guide

STELPRO STCP Floor Heating Thermostat Multiple Programming User Guide

STELPRO ST302P Programmable Electronic Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: INITIAL SETTINGS To begin with, follow the on-screen instructions to adjust your thermostat’s settings. Warning: Incorrectly connected electrical wires could result in a fire hazard. Complete the thermostat’s electrical connection according to the diagram below. If you selected MANUAL mode, your thermostat is now ready to use! If you selected PROGRAMMABLE mode, configure the following settings: The following table shows the default program values. The diagram shows a 240 V power supply. Important instructions: The thermostat must be installed by a certified electrician. This thermostat is programmable. Programmable mode allows you to define the setpoint temperature according to time of day and day of the week. To install this thermostat, you will need a #2 Phillips screwdriver. Warning: Turn off the power supply.