SECURE radbot 1 Intelligent Radiator Thermostat Instruction Manual
Technical specifications
Product description
Electronic radiator controller
incorporated control, type 1 action
Recommended use
Residential/similar use,
indoor only
Type code
SCV100
Size (including retaining ring)
Weight (including batteries)
Power
L x W x H = 90 mm x 55 mm x 55 mm
Approx 164 grams
2 x 1.5 V (LR6) AA alkaline batteries
Power consumption
Battery life (normal operating conditions)
Temperature range (working)
Temperature range (storage)
Max water circulation temperature
Temperature set point range
Temperature set point interval
Motor
3 μW sleep, 1.5 W peak
2 years
0 to 40°C
-20 to 60°C
90°C
15°C to 24°C, Frost protection 6°C
1°C
Linear motion 5.8 mm max
Pin force
70 N max
Protection class
IP30
Pollution degree
2
Others
Ball pressure test verified at 75°C
LED pattern
Description
When
Name
Power-on
When the batteries are inserted
One long (~1s) flash to indicate
the device is active
Boost
On starting boost mode
Immediate long flash on releasing
the Boost button, medium flash
every 2s for two minutes and then
flash every 8s for up to about 30
minutes if the room is not dark.
Acknowledge
Low Battery
Acknowledging adjustment of
the dial
Single flash once the dial position
has been changed
Low battery warning
Repeated medium flash every 2s
until battery is exhausted or replaced.
Most Radbot 1 features will not
operate.
Fault
When a hardware or software
unrecoverable failure is
detected
Continual rapid flashing, more
than once per second, until battery
exhausted or replaced. Radbot 1 will
not operate.
15
| General | Details |
|---|---|
| Name | SECURE radbot 1 Intelligent Radiator Thermostat Instruction Manual |
| Make | SECURE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.2 MB |

SECURE ThermoPlus PRT1 Programmable Room Thermostat Instruction Manual

SECURE ThermoPlus AS2 Programmable Room Thermostat Instruction Manual

SECURE H3747 Smart Programmable Thermostat Installation Guide