PURGEAR STC-2304 Digital Thermostat User Guide
Description
F7
≤-1Fan startup earlier than the compressor
≥1Fan startup later than the compressor
Fan keep synchronous with the compressor
Fan continuous working without interrupt
Fan continuous working except for the defrosting
time and water dripping time.
0
C
D
F7 & F8are the difference between this unit and
STC-2303.
7. Set the defrosting
First, you should set the F2defrosting interval time, since
A. when F2 = 0, the defrosting function was
disabled, then F1, F3, F4, F5are useless;
B. When F2 > 0, The defrosting function works.
Next, configure the F5that is the defrost method,
A. F5 = 0, Defrost by Electric-Thermal.
B. F5 = 1, Defrost by Hot Gas from the
compressor reversal rotary.
Then, change the F6 value; it is the stop line for
defrosting.
At last, to configure other parameters.