TECHNICAL DATA  
Supply  
Load  
1
2
0
/
2
4
0
V
a
c
5
0
/
6
0
H
z
15A maximum (resistive load)  
1,800 W at 120 Vac  
Power  
3,120 W at 208 Vac  
3,600 W at 240 Vac  
GFCI (UTN4-4999)  
EGFPD (ATN4-4999)  
Temperature range  
Floor limit range  
Class A (5 mA trip level)  
15 mA trip level  
+41 to +104°F (+5 to +40°C)  
+41 to +104°F (+5 to +40°C)  
82F(27.5C)  
Floor protection laminate/wood  
Floor protection tile  
Amb. Temp. range  
On/Off differential  
Regulation principle  
Housing  
88F(31.0C)  
+32 to +104°F (0 to +40°C)  
0.7°F (0.4°C)  
PWM / PI  
IP20  
Floor sensor type  
Dimensions(H/W/D)  
Wall box (H/W/D)  
NTC (10 KΩ) 15 ft (4.5 m)  
5.1/3.2/0.8 inch (130/82/20mm)  
3”/2”/2”  
c-UL-us according to the following standards:  
Thermostat:  
UL 60730  
CSA- E60730  
E157297  
UL E-file:  
GFCI:  
UL 943  
CSA C22.2, No. 144. 1-06  
Approvals:  
© 2015 OJ Electronics A/S  