SPECIFICATIONS:
Rated Voltage:
20V to 30VAC, 24VAC nominal
Rated A.C. / D.C. Current:
Temperature Control Range:
Thermostat Sensing Range:
Minimum Deadband:
0.05 to 0.75 AC / 0.0 to 0.75 DC Amp continuous, per output, surges to 3 Amps maximum
Heating: 38˚F to 88°F (4˚C to 31°C) in 1° steps Cooling: 60˚F to 108°F (16˚C to 42°C) in 1° steps
32˚F to 118°F (0˚C to 48°C) Control Accuracy: ±1°F @ 68°F (±0.5°C @ 20°C)
2°F (1°C)
Humidity Sensing:
Dimensions:
Range: 0% - 100% RH Accuracy: ±3% From 10% - 90%
5.1”H x 4.7”W x 1.15”D (130mm x 119mm x 29mm)
Equipment Terminations:
R - 24V switching voltage, W1 - Heat1 or Aux/Emer Heat, G - Fan, Y1-Compressor1,
Y2 - Compressor2, O/W2 - Heat2 or Rev. Valve in Cooling, B - Rev. Valve in Heating
24V(c) - Power Return, 24V - Separate Power (24VAC/DC) requires jumper removal
Power Terminations:
Input Terminations:
LED1 (Filter Icon Selectable), LED2 (Fault Icon Selectable), CLK1 ( + ), CLK2 ( - ) (Occupancy)
Remote Sensor Terminations: RS+V - Power, RS2 - Return, RS1 - Data
Wireless Radio:
Protocols:
2.4 GHz IEEE 802.11b/g/n, Security: WEP, WPA-PSK, and WPA2-PSK
http, native NetX API, BACnet/IP and Modbus TCP/IP over Wi-Fi
WIRING DIAGRAMS:
*24V for separate power (24VAC/DC).
Requires jumper removal on faceplate.
INPUT,
OCCUPANCY,
SENSOR
HVAC CONNECTIONS
CONNECTIONS
24Vac INPUT #1
L E D 1
L E D 2
C L K 1
C L K 2
R S 2
COMPRESSOR #2
24Vac INPUT #2
Y 2
W 1
Y2
HVAC
Equipment.
HEAT #1 or AUX/EMER HEAT
OCCUPANCY IN ( + )
W1
Y1
G
OCCUPANCY IN ( – )
COMPRESSOR #1
FAN
24 VAC*
Y 1
REMOTE SENSOR BUS - RTN
REMOTE SENSOR BUS - DATA
REMOTE SENSOR BUS - PWR
G
R
R
R S 1
Line
Voltage
2 4 V
2 4 V ( c )
O / W 2
B
R S + V
X 2 / A
X 1 / B
COMMON
C
O
B
HEAT #2 or AUX/EMER HEAT or
REVERSING VALVE
24 Vac
Transformer
Note: Check Heat Pump Installation Instructions
for reversing valve connection, either ‘O’ or ‘B’.
OUTPUT TERMINAL FUNCTIONS
Energizes compressor for second stage cooling, or for
heat pumps, either second stage heating or cooling
24Vac Input #1 for Filter or other Alert
LED1
LED2
CLK1
CLK2
RS2
Y2
24Vac Input #2 for Condensate, Fault or other Alert
For use with External Occupancy Sensor ( + )
For use with External Occupancy Sensor ( – )
Remote Sensor Bus (Power Return)
Remote Sensor Bus (Data)
Energizes heater for first stage heating, or for heat pumps,
aux/emer heat
W1
Y1
Energizes compressor for first stage cooling, or for heat
pumps, either first stage heating or cooling
Energizes fan circuit with a call for heating or cooling
G
R
RS1
Independent Switching Voltage from HVAC equip
Remote Sensor Bus (Power)
N/A
RS+V
X2/A
X1/B
24Vac
24V
N/A
24Vac Common
24V(c)
Energizes heater for second stage heating, or for heat
pumps, energizes the reversing valve in cooling mode
O/W2
B
Energizes the reversing valve in heating mode
| General | Details |
|---|---|
| Name | Network Thermostat X5-WIFI Smart Touchscreen Thermostat Instruction Manual |
| Make | Network Thermostat |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.24 MB |

Network Thermostat X7-Series Thermostat Installation Guide

Network Thermostat X7C-WIFI Smart Touchscreen Thermostat Instruction Manual

Network Thermostat NetXTM X-Series Thermostat Installation Guide

network thermostat NetX X5-CFA Universal Setback Thermostat Instruction Manual

network thermostat NetX X Series Thermostat Instruction Manual

network thermostat NetX X-Series Ethernet Thermostat Owner’s Manual

network thermostat X-Series Ethernet Thermostat Instruction Manual

Network Thermostat NetX X7 Series Thermostat Instruction Manual

network thermostat X X7-WIFI Smart Touchscreen Thermostat Instructions