Home > MERSCHEL iQ > MERSCHEL iQ MD2 Wired Thermostat User Manual
MERSCHEL iQ MD2 Wired Thermostat User Manual
MD2 WIRED THERMOSTAT
Technical Information:
Certifications:
Frequency
Wifi 2.4 Ghz
110 - 230VAC, 50/60Hz
5~45℃
Power Supply
Set Point Range
Ambient
EN60950 Information Equipment Safety
EMC ETSI EN301 489
0~50℃
Relative Humidity 85%
Radio ETSI EN300220
Backlight
Sensor
White
EMC EN61000-6-3: 2007 + A1: 2011 EMC EN61000-3-
2:2014
NTC 10K
3950ohms at 25℃
EMC EN61000-3-3: 2013
Accuracy ± 0.5℃ (step control by +0.5℃)
EMC EN61000-6-1:2007
Protection Class IP30
ISO 9001: 2008 Compliant Manufacture EN60730-2-
9:2010 with EN60730-1:2011
(Safety of Automatic Electrical Controls)
RoHS 2011/65/EC
Housing
ABS to UL94-5
fire retardant plastic
REACH 1907/2006/EC
Compliance
Hereby, Herschel Infrared Ltd declares that the radio equipment type MD2 Wireless Thermostat is in compliance
with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet
address:
Safety
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry.
This product must be installed by a competent person and in accordance with all the EU and national regulations.
Always isolate the AC mains supply before installing or working on any components that require 230V
AC 50 Hz mains.
This appliance is rated IP30 and must be installed outside of the splash zones in bathrooms.
| General | Details |
|---|---|
| Name | MERSCHEL iQ MD2 Wired Thermostat User Manual |
| Make | MERSCHEL iQ |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.3 MB |