Innova B3V151 Electronic Thermostat User Manual
M7 SERIES COnTROLS EEB749 - EFB749 - EGB749
4ꢀ3ꢀ8 Wi-FI reset
4ꢀ3ꢀ9 Activate Wi-FI
ToꢀresetꢀtheꢀWi-Fiꢀcredentialsꢀandꢀreturnꢀtheꢀdeviceꢀ
toꢀitsꢀoriginalꢀconfiguration
► select
ToꢀactivateꢀWi-Fi
► select
► press
to change settings
► press
to change settings
► use the
icons in sequence
► use the
icons in sequence
.
Appears
.
Appears
► press
► press
appears to enable Wi-Fi pairing.
appears to reset Wi-Fi credentials.
► press
to confirm
► press
to confirm
The device remains visible on the INNOVA App for
the first 15 minutes after the device is switched on.
Credentials have been reset.
The function is only available for wall controls with Wi-Fi
The function is only available for wall controls with Wi-Fi
ꢀ
ꢀ
connection code EFB749.
connection code EFB749.
4ꢀ4 Warnings
► E6
Incorrect water temperature with automat-
4ꢀ4ꢀ1 Long period shut-down
ic season function setting
For seasonal shutdowns or for long periods:
► disable the device
The fancoil is performing heating and cooling func-
tions incorrectly. None of the unit's functions can be
activated.
► set the main system switch to Off
The antifreeze function is not on.
ꢀ
► E8
Communication error alarm
Error in the communication between the wall con-
trol panel and the fancoil. None of the unit's func-
tions can be activated.
4ꢀ4ꢀ2 In case of control blockage
► h2o Incorrect water temperature
In heating mode, the water temperature is below 30
°C
This procedure should only be carried out in the event
ꢀ
that the control locks and no longer responds to com-
mands.
In cooling mode, the water temperature is above 20
°C.
In case of control blockage
► press both keys
and
for 10 seconds
Error E8 is displayed without the error display proce-
ꢀ
appears on the display accompanied by a beep.
The control was reset.
dure on the wall control panel.
4ꢀ4ꢀ4ꢀ ꢀResetꢀfilterꢀcleanerꢀalarm
4ꢀ4ꢀ3 Visualization of alarms on display
The flashing
symbol indicates that filter cleaning is
ꢀ
In the event of an alarm, the device still maintains active
ꢀ
required.
functions.
Afterꢀreplacementꢀofꢀfilters,ꢀitꢀisꢀnecessaryꢀtoꢀresetꢀ
theꢀcountꢀofꢀhoursꢀofꢀfilterꢀuse
ToꢀaccessꢀtheꢀSetupꢀmenu,ꢀitꢀisꢀnecessaryꢀtoꢀaccessꢀ
ꢀ
the Basic menu. See section "Basic menu" p. 13.
► press
for about 8 seconds
The
symbol disappears.
To visualise errors on the wall control panel
► access the basic menu
► press
Appears
► press
.
Appears
press
.
to access the menu
Next, the number assigned to the fancoil and the
alarm code appear.
Displayedꢀalarms
► E2 Faulty internal fan motor or disconnected
None of the modes can be activated.
► E3 Water temperature probe H2/T2 discon-
nected or failure
None of the modes can be activated.
► E5 H4/T3 heating water probe disconnected
or faulty
None of the modes can be activated.