HYSEN HY608 Wi-Fi Digital Heating Thermostat User Manual
NO
Setting Options
Measure Temperature
Calibration
Data Setting Function
-9-+9℃(Displayed as the corrected room
temperature value)
Factory Default
N1:Internal sensor (high temperature protection
close)
N2:External sensor (high temperature protection
close)
N3:Internal sensor control temperature ,external
sensor limit temperature (external sensor detect
the temperature is higher than highest
temperature of external sensor, thermostat will
Close relay,turn off load)
A1
-1
Start/stop working
temperature difference
setting
Children lock setting
Power on/off state
Options of sensor
control
BN
N1
A2
A3
0.5-2.5℃
1℃
0:half lock 1:full lock
0:Thermostat on/off with memory when
0
0
memory after electricity electrify
cut
A4
0: Disable descaling function
1:Thermostat off when electrify
Descaling
function
BC
Bo
0
2:Thermostat on when electrify
1: Enable descaling function
A5
A6
Standby bright
0: Off 1: Weakly bright 2: Brighter
2
0
product
Can’t be changed
0: 5+2
1: 6+1
2: 7
Weekly programming
selection
information
Setting temperature
minimum limit
Setting temperature
maximum limit
Return difference: limit valve of external sensor is 45℃ for factory default (A6),value of external
sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will
remind high temperature production alarm. If temperature decline to 43℃relay continue to work and
heating alarm will be relieved, (it can be operated ,only when room temperature is lower than setting
temperature ).
A7
A8
1-10°C
5°C
20-70°C
35°C
1-10°C
Low temperature
protection
Sensor fault display: please choose correct working way of built-in and external sensor, if choose
wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop
heating until the fault is eliminated
Warranty:
We offer the warranty of 24 months, from the sales day. The products of our company can have life time
A9
AA
AB
AC
When setting temp = 10℃, if press
display【--】, cancel low temperature protection
20°C-70°C
When setting temp =20℃, , if press
will
5°C
High temperature
protection for external
sensor
High temperature
protection temperature
difference setting
Window function
triggers temperature
will 45°C
display【--】, cancel high temperature protection
warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale
service.
1-9°C
2°C
Installation
5-60°C
--
When setting temp =5℃, if press
will
display【--】, cancel high window function
Window function
running time
Restore factory defaults
(Advanced Option A)
Heating/Cooling mode
AD
AE
AF
5-60min
10
0
Display Ao , long press
show
0: heating
key to whole icon
1: cooling
A
d
v
a
n
c
e
d
o
p
t
i
o
n
B
Power off state, long press
for 3-5 seconds to access advanced option B.
or , short press
short press
to choose the option, and adjust data by
to switch next
Factory Default
option.Remain about 5 seconds after finish setting will quit setting.
NO Setting Options Data Setting Function
| General | Details |
|---|---|
| Name | HYSEN HY608 Wi-Fi Digital Heating Thermostat User Manual |
| Make | HYSEN |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

HYSEN HY518WE WIFI Digital Heating Thermostat User Manual

HYSEN HY312 Wi-Fi Digital Heating Thermostat Instruction Manual

HYSEN HY510 WiFi Heating Thermostat Instruction Manual

HYSEN HY511 WiFi Heating Thermostat Owner’s Manual

HYSEN HY02B05RF Wireless Heating Thermostat User Manual

HYSEN HY09RF WI-FI Wireless Thermostat User Manual

HYSEN HY02DB-WIFI Wifi Plug In Thermostat User Manual