RTH5160 Series  
System Setup options  
System Setup Number and Description  
Options (factory default in bold)  
0 = Fahrenheit  
1 = Celsius  
125 = Temperature Indication Scale  
1 = Conventional Forced Air Heat  
2 = Heat Pump  
3 = Radiant Heat (Boiler)  
5 = None (Cool Only)  
200 = Heating System Type  
Note: This option selects the basic system type your thermostat will  
control.  
Conventional Forced Air Heat:  
1 = Standard Efficiency Gas Forced Air  
2 = High Efficiency Gas Forced Air  
3 = Oil Forced Air  
4 = Electric Forced Air  
5 = Hot Water Fan Coil  
Heat Pump:  
7 = Air to Air Heat Pump  
205 = Heating Equipment Type  
Radiant Heat:  
9 = Hot Water Radiant Heat  
12 = Steam  
Note: This option selects the equipment type your thermostat will  
control. This feature is NOT displayed if feature 200 is set to Cool Only.  
0 = O (O/B in Cool)  
1 = B (O/B in Heat)  
218 = Reversing Valve O/B  
Note: This option is only displayed if the Heat Pump configured. Select  
whether reversing valve O/B should energize in cool or in heat.  
0, 1, 2  
220 = Cool Stages / Compressor Stages  
(200=Conv / 200=HP)  
Note: Select how many Cool or Compressor stages of your equipment  
the thermostat will control. Maximum of 2 Cool stages or 1 Compressor  
stage. Set value to 0 if you do not have Cool Stage/Compressor Stage.  
Heat Stages: 1, 2  
Backup Heat Stages: 0, 1  
Note: Select how many Heat or Aux/E stages of your equipment the  
thermostat will control. Maximum of 2 Heat Stages for conventional  
systems. Maximum of 1 Aux/E stage for systems with more than 1  
heating equipment type. Set value to 0 if you do not have Heat Stage/  
Backup Heat Stage.  
221 = Heat Stages / Backup Heat Stages  
0 = Manual  
1 = Automatic  
Note: Thermostat can automatically control both heating and cooling  
to maintain the desired indoor temperature. To be able to select  
“automatic” system mode on thermostat home screen, turn this feature  
ON. Turn OFF if you want to control heating or cooling manually.  
300 = System Changeover  
NOTE: Once you have cycled through all of the System Setup numbers, press  
Done to save and exit to the home screen.  
Setup Complete  
You have now finished installing and setting up your thermostat.  
9
GeneralDetails
NameHONEYWELL RTH5160 Series Non-Programmable Thermostat Installation Guide
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size1.15 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

HONEYWELL RTH5160 Series Non-Programmable Thermostat Installation Guide