Honeywell 191108AJ Series Heating or Cooling Thermostat User Guide
temperature (comfort period); a blue pin is
inserted at 10:00 PM for low temperature
(energy saving period). Two additional sets of
pins are located in the program pin storage
area. You can set up to six temperature
changes with the pins supplied. We recom-
mend at least five hours for each energy
saving period.
reset the pins when the seasons change.
You will also probably want to change the
lever positions.
To set the heating program:
■ Decide when you want the temperature to
reach the comfort level. Find the notch on the
dial that is one-half hour before this time and
insert a red pin. The high temperature is in
effect. The half-hour head start gives the
furnace time to heat the house before you
awaken or arrive home.
■ To change the pins or add a new energy
savings period:
•
To insert a pin, push it straight into the
selected notch on the program dial until it is
completely seated.
■ Decide when you want the energy saving
period to start and insert a blue pin at the
notch that corresponds to this time. After the
blue pin engages, the low temperature is in
effect. The furnace will be off until room
temperature drops to the energy saving
setpoint.
•
To remove a pin, press against the
program dial and pull the pin straight out.
DO NOT attempt to change a pin if it is
engaged with the program index wheel.
On heating/cooling systems, set the
subbase switches to desired positions. See
Setting Subbase Switches section.
On heating/cooling systems, you must
•
•
■ You can set both a day and a night program.
See Fig. 5 for program examples.
11
firealarmresources.com
69-0643—1
WINTER
PROGRAM
SUMMER
PROGRAM
To set the cooling program:
TEMPERATURE
TEMPERATURE
PIN IN
PIN IN
CONTROL
°F
°C
27
CONTROL
°C
14
°F
■ Decide when you want the temperature to
reach the comfort level. Find the notch on the
dial that is one-half hour before this time and
insert a blue pin. The low temperature is in
effect. The half-hour head start gives the air
conditioner time to cool the house before you
awaken or arrive home.
NIGHT
BEGINS
58
BLUE
RED
80
RED
BLUE
RED
ENERGY
SAVING
PERIOD
10:00 PM
ENDS
6:00 AM
68
58
68
24
27
24
20
14
20
75
80
75
DAY
BEGINS
7:30 AM
BLUE
RED
ENERGY
SAVING
PERIOD
ENDS
4:00 PM
BLUE
M1690B
■ Decide when you want the energy saving
period to start and insert a red pin at the
notch that corresponds to this time. After the
red pin engages, the high temperature is in
effect. The air conditioner will be off until the
room temperature rises to the energy saving
setpoint.
Fig. 5—Programming examples.
12
firealarmresources.com
69-0643—1
| General | Details |
|---|---|
| Name | Honeywell 191108AJ Series Heating or Cooling Thermostat User Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.17 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide